![NKE 90-60-545 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/nke/90-60-545/90-60-545_user-manual-and-installation-manual_1697327007.webp)
7
67_Pad_Display_UM_UK_13
4.2 Shortcut Pages A, B, C, D
Keys A, B, C, D are used to call up programmed pages or the standby command in
the Multigraphic and Multidisplay displays.
Example: I have a Pad Display, a Multidisplay and a Multigraphic in my Topline
installation. My two displays have the A key programmed. When I press the A key on
my Pad, I bring up the programmed page of each display. For the display standby
command, pressing once switches the display to standby and then waking it up.
4.3 Timer
4.3.1 Key TIMER and SYNC
TIMER and SYNC direct access to the timer. For pressing these keys to have an
effect it is necessary that:
A page with the TIMER channel has been created on at least one bus display.
That in the reactions to the SYNC shortcut the display of the page in question has
been programmed. Settings menu> Shortcut configuration> Sync shortcut - Goto
page X.
3 states for the TIMER :
1/ Not ready, no number is displayed ----
2/ Ready to launch. The time T1 is displayed.
3/ In process, the time decrease.
At first display the TIMER channel:
- To synchronize the TIMER, push longtime on
, T1 is display.
- To change T1 push on
one or many time.
- To launch TIMER push on
.
- If you have delay, synchronize at the closest minute. Push
.
Ex : If the TIMER display 1mn32 it will synchronize at 2mn and if the display
1mn24, it will synchronize at 1mn.
- To stop the TIMER push
and push again
for restart the TIMER.
- To prepare the TIMER push long time