Shutdown the PC while battery mode: When selected, integrated with 

Shutdown Wizard, local PC will shut down while UPS works on battery 

mode.

• 

Time needed for shutting down the PC: Enter the delay time to shut down 

the operating system.

• 

The PC should:
1.  Shutdown: When clicking the checkbox, the selected system will shut 

down. The default setting is clicked.

2.  Sleep mode: When clicking the checkbox, selected system will suspend 

the system instead of a normal shutdown. But this function is only 

supported by Windows 2000 or higher on supported hardware.

• 

Also power off the UPS after shutting down the PC: When click the check

-

box, monitored UPS will turn off after local system shuts down. The UPS 

shutdown time will be later than system complete shutdown time. Users 

can choose to shut down the system without shutting down the UPS.

• 

Shutdown UPS output after xx sec: It will cut off UPS output after moni

-

tored UPS works on battery mode for xx sec.

• 

Shutdown the PC while low battery: When clicking this checkbox, local 

PC will shut down when monitored UPS battery is running low.

• 

Wake on LAN while AC recovery: When clicking this checkbox, the local 

PC will be wake on LAN while AC recovery.

• 

Send E-mail while any UPS event occurs: When clicking this checkbox, it 

will send alarm E-mail when any event occurs on the local UPS.

• 

Send SMS while any UPS event occurs: When clicking this checkbox, in 

the event of an alarm condition occurring, a message about UPS status 

will be sent to the specified users via mobile phone.

• 

EMD alarming temperature upper limit: Set up alarm for high temperature 

point. If detected temperature is beyond setting value, it will send alarm 

message.

• 

EMD alarming humidity upper limit: Set up alarm for high humidity point. 

If detected humidity is beyond setting value, it will send alarm message.

• 

Data record interval xx sec: Data log record the data per xx sec.

4.4.7 Scheduled

Select 

System Configuration >> Scheduled

. Refer to Chart 4-12.

Chart 4-12

• 

Scheduled battery selft est: Scheduled battery selft est can be executed 

once, daily, weekly, or monthly. Users can select UPS and time parame

-

ters. It is recommended to set only one action in the same time. If mul

-

tiple actions have been applied at the same time, some of these actions 

may be ignored. Any action will be ignored when the action is not sup

-

ported by the UPS.

• 

Scheduled UPS on/off: Scheduled UPS on/off can be executed once, daily, 

weekly. Users can select UPS and time parameters. It is recommended to 

set only one action in the same time. If multiple actions have been applied 

at the same time, some of these actions may be ignored. Any action will 

be ignored when the action is not supported by the UPS.

Содержание ACUP-SN000MP-AZ01B

Страница 1: ...SNMP Card WP User manual ACUP SN000MP AZ01B Before using this product carefully read all product documentation and retain it for future reference 111 0...

Страница 2: ...ion Menu 10 4 1 Information 10 4 1 1 Status 10 4 1 2Basicinformation 10 4 2 UPS setting 11 4 2 1Parameterssetting 11 4 3 Control 13 4 3 1Real timecontrol 13 4 4 System configuration 13 4 4 1 Web user...

Страница 3: ...port data transmission port Golden finger connects to UPS slot Ethernet port status LEDs Jumper setting to restore default setting Ethernet port status LEDs 100M LED Green On Port is operating at 100M...

Страница 4: ...30 default subnet mask as 255 255 255 0 and default gateway as 192 168 102 254 Users can modify IP address or apply DHCP mode through web server of SNMP web pro card SSH Client or SNMP Web Manager Cha...

Страница 5: ...includes function menu login section and main screen Refer to Chart 3 1 Chart 3 1 A SNMP web pro GUI version B Function Menu It offers complete tool set for navigation and setting the GUI C Main Scree...

Страница 6: ...ing for bypass mode and voltage range setting for ECO mode Select UPS setting Parameters setting Refer to Chart 4 4 Chart 4 4 NOTE Different UPSs may access different parameter setting 1 Select the fu...

Страница 7: ...et setting Users can set limited backup time for P1 outlets when UPS is on battery mode Battery numbers setting Set battery numbers in parallel Voltage and frequency range for bypass mode Set acceptab...

Страница 8: ...ccessfully sent to specific recipients it will pop up a suc cessful message on operated PC Otherwise it will pop up a failure dialog to indicate there is an error for parameter setting 4 You may decid...

Страница 9: ...hardware support for remote PCs to implement this function 4 4 5 Shutdown It is to remotely shut down specific PCs with Shutdown Wizard This function is only available to integrate with Shutdown Wiza...

Страница 10: ...king this checkbox it will send alarm E mail when any event occurs on the local UPS Send SMS while any UPS event occurs When clicking this checkbox in the event of an alarm condition occurring a messa...

Страница 11: ...p IP address SNMP UDP port add delete snmpv3 user account and restore the factory settings NOTE Some modifications are required to restart snmp server to become effective Select System Configuration S...

Страница 12: ...as csv file The event log includes UPS warnings fault info EMD warnings UPS oper ation logs from web users or ViewPower pro users All logs are recorded in flash memory of web card by month It s safely...

Страница 13: ...the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical a...

Страница 14: ...Memo Memo...

Страница 15: ......

Отзывы: