IMPORTANT

Installer and Users please note:

These instructions should be read carefully and left

with the user of the product for future reference.

Installation

The  Euro  8s  must  be  installed  by  a  competent

electrician  in  accordance  with  the  current  IEE  wiring

regulations.

CONNECTION

The  Euro  8s  is  not  fitted  with  a  mains  plug.  This  is

because:

i) it is capable of controlling more than 13 Amps
ii) it may be installed permanently
iii) it is an appliance for professional use.
Connect the Euro 8s to the mains supply with the built in

mains lead, Connect the wires as follows:

• Brown = live
• Blue = neutral
• Green/yellow = earth
• The Euro 6s must be earthed

Connect the output loads to the IEC sockets on the rear

panel  using  IEC  plugs.  The  sockets  are  directly  behind  the

switch for each channel.

• 

For a 15A supply

, the maximum total load is 3450W

which can be made up of:

either:

 430W watts on each of the eight channels

or:

  different  loads  on  each  channel  so  that  the  total

Содержание Euro 8s

Страница 1: ...onnections Interference free switching The Euro 8s is an 8 channel switch panel providing eight mains outputs each with its own fuse and indicator zero switched for interference free operation The Eur...

Страница 2: ...pable of controlling more than 13 Amps ii it may be installed permanently iii it is an appliance for professional use Connect the Euro 8s to the mains supply with the built in mains lead Connect the w...

Страница 3: ...or loads of up to 1150W may be connected to all eight channels provided that the unit is operated so that the total load that is switched on at any one time does not exceed 2990W Inductive loads If c...

Страница 4: ...its setting up procedure which happens with all intelligent motorized lighting effects Lighting controllers A lighting controller such as the NJD SC4000e or CC4000s may be connected to an output of t...

Страница 5: ...atus connected to the faulty channel for short circuits and check to make sure that the output has not been overloaded Disconnect the supply and replace with type BTA12 600B or equivalent This involve...

Страница 6: ...o a resistive load of 3450 Watts or an inductive load of approximately 2400 Watts depending on power factor Reduce to 13 Amps 2 99kVA if connected using a British BS1363 mains plug and socket Power re...

Страница 7: ...nics 2001 Page 7 User Guide Euro 8s Safety Standards The Euro 8s complies with EN60065 European Electrical Safety Standard EN55103 Electromagnetic Compatibility Standard EN60297 Standard for Fascia pa...