Nivetec Signet 2760 DryLoc Скачать руководство пользователя страница 6

6

Signet 2760 DryLoc pH/ORP Preampli

fi

 er

Standard output,
¾ in. process connector.

3-2774
3-2775
3-2776
3-2777

Differential output,
1 in. process connector.

3-2764-1
3-2765-1
3-2766-1
3-2767-1

Standard output,
Signet installation fittings

3-2724-10, -11
3-2725-60, -61
3-2726-10, -11
3-2726-HF-10, -11
3-2726-LC-10, -11
3-2756-WTP-1
3-2757-WTP

3-2760-1
3-2760-2

3-2760-1
3-2760-2

3-2760-11

3-2760-21

3-5700 pH/ORP Monitor

V +

Red Wire

V -

Black wire

-

+

T -

White wire

T +

Green wire

Iso. Gnd

Blue wire

Blue Iso. Gnd

mV Input

Brown wire

Brown mV

4-20 

mA

Red V+

Black V- 

White T-

Green T+

Connect this terminal     to Earth GND to reduce electrical interference.

White (Temp)

Green (Temp)

Blue (Iso. Gnd)

Brown (mV input)

Shield

Black (V-)

Red (V+)

12

11

10

9
8
7
6
5

18
17
16
15
14
13
12

11

16
15
14
13
12

11

10

9

3-8750-1

3-8750-2

3-8750-3

ProcessPro pH/ORP Transmitter

3-2760-11

3-2760-21

Any of these electrodes can be connected to the Signet ProPoint and ProcessPro pH instruments using the 3-2760-1(X) or -2(X) 
Preampli

fi

 ers.

Wiring diagrams illustrate the actual terminals on these products for convenience.

R LA  1 

 

Signet 8750-X
ProcessPro pH/ORP Transmitter

Signet 5700
ProPoint pH/ORP Monitor

Wiring to Signet Instruments

Содержание Signet 2760 DryLoc

Страница 1: ...H and ORP electrodes to supply an amplified mV analog signal to Signet instruments 3 2760 090 3 2760 090 Rev 9 01 18 Description Table of Contents English Deutsch Français Español Product Manual Warranty Statement 2 Product Registration 2 Safety Information 2 Chemical Compatibility 2 Specifications 2 Dimensions 3 In Line Assembly and Installation 3 4 Wet Tap Assembly and Installation 4 Submersible...

Страница 2: ...on warranty repairs being returned must include a fully completed Service Form and goods must be returned to your local GF Sales office or distributor Product returned without a Service Form may not be warranty replaced or repaired Signet products with limited shelf life e g pH ORP chlorine electrodes calibration solutions e g pH buffers turbidity standards or other solutions are warranted out of ...

Страница 3: ...ocked When fully assembled the 2760 will stand about 100 mm 4 in above the installation fitting Lock Unlock 100 mm 4 in Lubricate O rings 1 2 3 4 5 2760 In Line models used with 2764 2767 or 2774 2777 series electrodes BEFORE YOU START 2764 2767 Install a 1 in NPT pipe tee into the process line 2774 2777 Install a in reducing tee into the process line 1 Wrap the process threads on the electrode wi...

Страница 4: ... tee in the process line DO NOT install in a inch tee or probe will be damaged 1 Wrap the process threads on the electrode with an appropriate sealant example PTFE tape to create a water tight connection 2 Lubricate O rings with a non petroleum based viscous lubricant grease compatible with the system 3 Remove the threaded nut from the preamplifier and place it around the electrode from the bottom...

Страница 5: ...ier dry and clean at all times 3 Attach 3 4 in watertight pipe to the top of the 2760 Secure the threaded connection to prevent any leakage Fill the lower 75 100 mm 3 to 4 in of conduit or extension pipe with a flexible sealant such as silicone to prevent liquid accumulation on the back seal of the 2760 OR OR The submersible 2760 can be installed in a tank or vessel if conditions are within pressu...

Страница 6: ...mV Input Brown wire Brown mV 4 20 mA Red V Black V White T Green T Connect this terminal to Earth GND to reduce electrical interference White Temp Green Temp Blue Iso Gnd Brown mV input Shield Black V Red V 12 11 10 9 8 7 6 5 18 17 16 15 14 13 12 11 16 15 14 13 12 11 10 9 3 8750 1 3 8750 2 3 8750 3 ProcessPro pH ORP Transmitter 3 2760 11 3 2760 21 Any of these electrodes can be connected to the Si...

Страница 7: ...le 3 2760 1 3 2760 2 DryLoc Preamplifier In Line 3 2760 11 3 2760 21 White Temperature Green Temperature Blue mV Reference Shield Earth Ground Black V Red V Brown Active mV pH ORP Signet Combination pH Electrodes 3 2724 10 3 KΩ NPT 3 2724 11 3 KΩ ISO 3 2726 10 3 KΩ NPT 3 2726 11 3 KΩ ISO 3 2726 HF 10 HF Resist 3 KΩ NPT 3 2726 HF 11 HF Resist 3 KΩ ISO 3 2726 LC 10 Low Cond 3 KΩ NPT 3 2726 LC 11 Low...

Страница 8: ...ings 3 2726 10 159 001 555 Bulb glass pH Electrode 3 KΩ RTD in NPT or Signet fittings 3 2726 11 159 001 556 Bulb glass pH Electrode 3 KΩ RTD ISO 7 1 R or Signet fittings 3 2726 HF 10 159 001 551 Bulb glass pH Electrode 3 KΩ RTD HF resistant in NPT or Signet fittings 3 2726 HF 11 159 001 552 Bulb glass pH Electrode 3 KΩ RTD HF resistant ISO 7 1 R or Signet fittings 3 2726 LC 10 159 001 559 Bulb gla...

Отзывы: