16 / 28
tmh5554a0600p_06
tmh555en2106p
5.2.
P
ROGRAMMING WITH THE
SAP
−
300
DISPLAY MODULE
When entering the menu, the device copies the current parameter set, and all changes are made in this duplicate. The instrument keeps measuring and transmitting
values in accordance with the current (and intact) parameter set while programming. After exiting the menu, the instrument replaces the original parameters with the
new parameter set and starts measuring in accordance with the new parameters. This means that pressing the E button after changing the parameters does not
immediately make the new parameters effective!
Pressing the
E
button to enter the menu. Press the
E
button to exit the menu.
If the device is left in programming mode, it will automatically return to measuring mode, and all changes will be unsaved after 30 minutes. If the SAP
−
300 is
removed, the instrument will immediately exit from the menu, and all changes will be discarded.
Programming the device with the SAP
−
300 (manual programming) and HART (remote mode) at the same time is not possible. However, the measured values can be
read through HART at any time.
5.2.1
Components of the programming interface
The parameters of the instrument are grouped by their functions. The programming interface consists of lists, dialog windows, editing and report windows.
Lists
Navigate between the lines of lists by pressing the / buttons. Pressing the
E
button activates the list item under the
cursor. The cursor is the inverted line under which the items are cycled. Exit from a list by pressing the button.
Menu list
The menu list is a special list. Its characteristic is that upon selecting an item will invoke a sub-list. The menu header (1)
helps navigate the menu.
Enter the menu by pressing the E button. Navigate between the menu items by pressing the / buttons. Enter
E
to the
selected menu by pressing the E button. The selected list item is marked with inverse color.
Exit from a sub-menu with the button. Press the button in the main menu to exit programming mode, and the
instrument will return to measuring mode.
Dialog window
The system sends messages or warnings using dialog windows. They can usually be acknowledged by pressing the
button, or the choice between two options is offered, usually YES ( button) and NO ( button). In some cases, a
parameter has to be changed to correct an error!