Start/Torque-up signal outputs
This controller has a function of outputting start/torque-up signals, which can be used for measures to verify the
number of screws to be tightened and prevent the screws from remaining loose.
As the output signals are photo coupler outputs which do not require an external power supply or an auxiliary circuit,
signal processing is easy since direct connections can be made to a sequencer and so on.
CAUTION
Before energizing, make sure that the signal cables are wired correctly in accordance with the instruction
manual.
If the power cable or other signal wires are energized while they are wired incorrectly, it could cause the tool to
fail.
Always use the signal output within the output rating.
Use of the tool at a voltage or current value above the rating could cause the tool to fail.
Do not directly connect the relay, motor, lamp, etc. to control.
It could cause the tool to fail due to surge, etc. generated from inductive load.
The start signal will be outputted.
Signal output
Open collector
Rated voltage
80 V DC or less
Rated current
Maximum 50 mA or less
Output signal timing chart
Lever switch
OFF
ON
Start (
1
-
2
)
Torque up (
1
-
3
)
Torque up
Terminal number - Internal circuit
2
Start
3
Torque up
1
GND