2) Connect up the coaxial outputs of the unit. The coaxial ports are designed for connection with 75 ohm solid copper 

coaxial cable, commonly RG-59 or RG-6. The coaxial port is a 100Mb network port. It is important that the coaxial 
connectors be in good condition. The speed of the connection and POE status is indicated on the front panel of the 
unit. A transmitter must be connected to the other end of the coaxial cable for the connection speed to be indicated 
and for the POE to turn ON.    

Head-end Installation  
ER8500C and ER16500C 

 

1) 

The ER8500C / ER16500C can be rack mounted, wall mounted or used as desk top unit. Use the included mounting 
ears in the front or back of the unit depending on your needs. The mounting ears can also be turned to the bottom of 
the unit for wall mounting if needed. When mounting the unit, be sure to follow these guide lines.

 

a.  Operating Ambient - Do not install the unit in an assembly where the ambient temperature could exceed 52°C 

(125°F).  NOTE: the ambient temperature in a closed or multi-unit rack assembly could greatly exceed the ambi-
ent temperature outside that assembly. 

b.  Air-Flow – Leave space on the sides of the unit for airflow into the cooling fans and some space on top of the 

unit for air to exit the unit.  Adequate air flow is required for safe operation. 

c.  Mechanical Loading – The mounting ears were designed for two ears to support one unit.  Other configurations, 

such as mounting other equipment directly on top of the unit or using only one mounting ear, could cause a haz-
ardous condition due to uneven or excessive mechanical loading. 

d.  Circuit Loading - Do not connect the unit to an electrical supply if the wiring or over current protection of the sup-

ply could be overloaded when the ratings listed on the unit are considered. 

e. 

Grounding (Earthing) - Reliable earth grounding of rack-mounted equipment should be maintained, use only 3 
conductor equipment power cords.  If the unit is plugged into a power strip or extension cord, that strip or cord 
should have a ground (third) pin on its plug.

 

Front 

Back 

Rack Mounting 

Options 

Wall Mounting 

Options 

SFP Ports 

LAN Ports 

Coaxial  
Network Ports 

Power Jack 

Содержание EtherStretch ER8500C

Страница 1: ...any heat sources such as radiators heat registers stoves or other appara tus that produce heat Patent Pending USA and Europe Euro Pat App 2779641 NITEK De Aar 99 8253 PN Dronten The Netherlands Tel 31...

Страница 2: ...E the ambient temperature in a closed or multi unit rack assembly could greatly exceed the ambi ent temperature outside that assembly b Air Flow Leave space on the sides of the unit for airflow into t...

Страница 3: ...flashing slowly it will indicate that the network has a loop in it and data is cascading It is recommended to remove the second LAN jack if this occurs and see if the problem goes away The data speed...

Страница 4: ...n on followed by the LINK STATUS LED on the Network Port The IP camera or other Ethernet device should now be ready to operate Continue installing the remaining transmitters as needed Connector LED OF...

Страница 5: ...e maximum power available for your length of coax 11 If the needed level of power is not available for the length of coaxial cable alternate options are available One method is to directly power the t...

Страница 6: ...ort of the ER8500 ER16500 unit Go into the network setting for your PC and set its address to 192 168 1 100 and a subnet mask of 255 255 255 0 The default IP address of the ER unit is 192 168 1 1 ente...

Страница 7: ...onal rights Restricted will only allow this person to see the Home screen and the Log Out Screen POE On Off will allow a user to turn off power to individual transmitters and cameras and to make syste...

Страница 8: ...is from time to time updated to add fea tures to the unit These updates are mostly in the form of added features in this webpage section Firmware updates will be posted to the Nitek website at www ni...

Страница 9: ...perly setup This can lead to a false reading In this rare case Mode may need to be set to DM Discovery Mode to allow for cameras to be configured Once the cameras are properly configured the setting c...

Страница 10: ...each port at the ER8500C ER16500C end In this screen you can also turn on all of the POE ports or reset the whole unit is needed The Labels button takes you the screen where you can apply a custom la...

Отзывы: