Nitek ER8400C Скачать руководство пользователя страница 4

Installment Topology  

Equipment Requirements & Mounting: 

The process for installing the ER8400C is rather quick and easy. A com-

mon topology involves up to 8 new or existing coax cables (not exceeding 1600ft / 500m), up to 8 ET1500C trans-
mitters and up to 8 IP cameras or other peripheral network devices. The wall mounted ER8400C, which can be re-
ferred to as the NITEK Power Sourcing Equipment (PSE), is compliant with both 802.3AF and 802.3AT devices.   
 
The method for facilitating Ethernet communication and PoE over a coaxial cable starts with connecting the 
ER8400C up to 8 coaxial cables via its BNC jacks. Each of the coaxial cables interface with the IP camera via the 
ET1500C transmitter, located at the camera end of the cable. The IP camera establishes connectivity to ET1500C 
transmitter via RJ5 jacks and a CAT5e/CAT6 patch cords. The ER8400C powers all attached devices within this 
system. The Ethernet data from the camera is transmitted over each individual coaxial cable through the ET1500C 
to the wall mounted ER8400C in either the IDF or MDF. The aggregate Ethernet data is transmitted to the LAN port 
via a built-in Layer 2 switch of the ER8400C. The Gigabit LAN port to ensure congestion-free throughput. An illus-
tration of this system is shown below in the “Installment Topology” diagram. 
 
Upon power up the devices will undergo initialization and auto-configuration which may take a number of seconds 
(time variations are device, installation and topology dependent) to complete before PoE and Ethernet communica-
tion commences. For optimal performance referring to the PoE Distance Chart later in this manual. Also adhering to 
the IP camera operational specifications is recommended. If issues arise during the installation process please see 
the “Trouble Shooting Tips” section later in this manual. You may also contact our web based live tech support at: 

www.nitek.net 

or call (800) 528-4343 in order to speak with one of our engineers directly. 

Installation & Setup 

Содержание ER8400C

Страница 1: ...tion and PoE transmission to be extended to 500 meters or 1600 feet The ER8400C is a fully functional PoE Layer 2 switch with IEEE802 3AT power output on each of the 8 EtherStretch ports and a full Gi...

Страница 2: ...ical supply if the wiring or over current protection of the supply could be overloaded when the ratings listed on the unit are considered Protect the power cord from being walked on or pinched especia...

Страница 3: ...se the signal conductivity of the cables For more specific information regarding wire types gauges and proper installation techniques please call Tech Support at 800 528 4343 Ethernet PoE The ER8400C...

Страница 4: ...system The Ethernet data from the camera is transmitted over each individual coaxial cable through the ET1500C to the wall mounted ER8400C in either the IDF or MDF The aggregate Ethernet data is trans...

Страница 5: ...retch ports The EtherStretch ports are 10 100Mb speed and will run at the highest possible speed given the wire condi tions The ER8400C works like a standard network switch for Ethernet devices but ov...

Страница 6: ...unicate at up to 1Gbps The LAN port will automatically sense the connection speed of the net work switch NVR or server The LAN port is NOT POE capable only the network ports can provide power to con n...

Страница 7: ...Ethernet device does not need to be connected for the transmitter to communicate with the head end Finally connect an Ethernet device to the transmitters Network Port If the device requires PoE power...

Страница 8: ...E device connected this would indicate you are having a current limit problem You should first check the power requirements of the PoE device Also check the length of the Link cable from head end to t...

Страница 9: ...0 Feet 100 Meters 328 Feet 21 7 Watts 21 7 Watts 18 2 Watts 14 4 Watts 12 2 Watts Available PoE Wattage At PoE Device Watts Results charted were calculated using RG59U coaxial cable with a 20AWG cente...

Страница 10: ...Unit Dimensions 10 6 10 6 4 0 IEC380 Connector Security Lock...

Страница 11: ...EEE 802 3af IEEE 802 3at standards per BNC connector Troubleshooting Technical Specifications PROBLEM POSSIBLE CAUSE No video data Check camera and ER8400 ET1500 device connections Check Coax cable co...

Страница 12: ...t charge for parts and labor or will provide a replacement in exchange for the defective product In order to obtain service under this warranty the customer must notify NITEK of the defect and shall b...