Nitek ER8400C Скачать руководство пользователя страница 3

Parts of the ER8400C (Front Panel)  

LAN

ETHERSTRETCH

NITEK

®

POWER

TROUBLE

10 Mbps

100 Mbps

1000 Mbps

LAN

PoE
10 Mbps
100 Mbps

PORT 1

PORT 2

PORT 3

PORT 4

PORT 5

PORT 6

PORT 7

PORT 8

8

7

6

5

4

3

2

1

Network Connection   

Green

 

 

 = 1Gb  

Yellow

Yellow

Yellow

 

 

 = 100Mb 

Orange

 = 10Mb 

Coax BNC Connectors 

LED Display Panel 

The LED Display Panel shows the same 
information as the individual jacks does but 
in a easier to read location. It also shows 
Power indicator and a Trouble LED. 

 

Trouble LED 

Solid

 if there is a temperature problem 

Flashing Slow 

is a network loop problem 

Installation Considerations 

Wire and Cable Recommendations: 

The ER8400C is designed for use with up to 8 coaxial cables. The quality 

and condition of which must be considered serviceable cable. It must be free from damage such as cuts, breaks or 
cracks to the outer covering and insulated shielding which may compromise the signal conductivity of the cables. 

For more specific information regarding wire types, gauges, and proper installation techniques please call Tech 
Support

 

at (800) 528-4343

.

 

Ethernet & PoE: 

The ER8400C is designed to communicate at up to 100Mbps per network port for Ethernet data 

and transmit up to a Gigabit of aggregate LAN traffic. Additionally, the ER8400C provides per port power sourcing 
PoE+ voltage to operate the transmitters (ET1500C), and up to 8 attached network devices. As a power sourcing 
Layer 2 switch the ER8400 will supporting 15.4W (802.3af) to 25.5W (802.3at) powering schemes at a maximum 
distance of 1600ft or 500m. Refer the PoE distance chart for specific power capabilities. Before installing this solu-
tion be sure that the cable involved does not exceed the recommended maximum lengths. If the cable length is in-
determinist at the time of installation, we recommend the use of a time domain reflectometer (TDR) which can 
measure impedance characteristics, splices, and determine the cable length. The TDR does this through the use of 
short rise time pulses.  
 

Содержание ER8400C

Страница 1: ...tion and PoE transmission to be extended to 500 meters or 1600 feet The ER8400C is a fully functional PoE Layer 2 switch with IEEE802 3AT power output on each of the 8 EtherStretch ports and a full Gi...

Страница 2: ...ical supply if the wiring or over current protection of the supply could be overloaded when the ratings listed on the unit are considered Protect the power cord from being walked on or pinched especia...

Страница 3: ...se the signal conductivity of the cables For more specific information regarding wire types gauges and proper installation techniques please call Tech Support at 800 528 4343 Ethernet PoE The ER8400C...

Страница 4: ...system The Ethernet data from the camera is transmitted over each individual coaxial cable through the ET1500C to the wall mounted ER8400C in either the IDF or MDF The aggregate Ethernet data is trans...

Страница 5: ...retch ports The EtherStretch ports are 10 100Mb speed and will run at the highest possible speed given the wire condi tions The ER8400C works like a standard network switch for Ethernet devices but ov...

Страница 6: ...unicate at up to 1Gbps The LAN port will automatically sense the connection speed of the net work switch NVR or server The LAN port is NOT POE capable only the network ports can provide power to con n...

Страница 7: ...Ethernet device does not need to be connected for the transmitter to communicate with the head end Finally connect an Ethernet device to the transmitters Network Port If the device requires PoE power...

Страница 8: ...E device connected this would indicate you are having a current limit problem You should first check the power requirements of the PoE device Also check the length of the Link cable from head end to t...

Страница 9: ...0 Feet 100 Meters 328 Feet 21 7 Watts 21 7 Watts 18 2 Watts 14 4 Watts 12 2 Watts Available PoE Wattage At PoE Device Watts Results charted were calculated using RG59U coaxial cable with a 20AWG cente...

Страница 10: ...Unit Dimensions 10 6 10 6 4 0 IEC380 Connector Security Lock...

Страница 11: ...EEE 802 3af IEEE 802 3at standards per BNC connector Troubleshooting Technical Specifications PROBLEM POSSIBLE CAUSE No video data Check camera and ER8400 ET1500 device connections Check Coax cable co...

Страница 12: ...t charge for parts and labor or will provide a replacement in exchange for the defective product In order to obtain service under this warranty the customer must notify NITEK of the defect and shall b...

Отзывы: