Receiver Unit
Network Output Port
1 RJ45 Connector @ 1 Gigabit
Link Port
8 BNC Connectors @ 100Mbps each
Dimensions
10.6”W x 10.6”H x 4.0"D
Operating Temperatures
0° to 52° C / 32° to 125° F
Shipping Weight
12 lbs
Shipping Dimensions
12”W x 12”H x 6”D
Power Requirements
IEC380 connector - 110-240VAC/50-60Hz/320Watt Max
LED Connectivity Indicators
Link Status, Power, PoE Out, 10/100/1000Mb
Mounting Wall
mounting
Humidity
Up to 95% non-condensing
Power Output
204 watts Max.
PoE Capabilities
Compliant w/ IEEE 802.3af & IEEE 802.3at standards per BNC connector
Troubleshooting
Technical Specifications
PROBLEM
POSSIBLE CAUSE
No video/data
Check camera and ER8400/ET1500 device connections.
Check Coax cable condition and BNC connector terminations.
Check that the camera is powered.
Check that supplied camera power meets manufacturer’s
specifications.
Check
cable
that
cable
distances do not exceed PoE capabilities.
Check
that
Coax
cable
length
does not exceed the operating distances
of
the
ER8400
&
ET1500.
Check
link
&
device
status
LEDs.
Video/data loss
Check network switch terminations & link status.
Check
network
routing
table.
Confer
with
site
Network
Administrator
For Tech Support Call 1-(