4 ch Field Mixer FS-40X

Parts Names and Funcctions

Main panel (Front)

L     :  When mixing to L channel.
C    :  When mixing to both L and R channel.
R    :  When mixing to R channel.
MS  :  When only using the MS microphone connected to the MS IN connector or
          3 and 4 IN connectors. (only for CH 3 and 4) 
OFF :  The signal is not mixed. (only for CH 1 and 2) 

L/C/R/MS Output Channel Select switch

Select the output channel, L or R, to mix each of the 1 to 4 CH input signals 

adjusted independently.

CH Fader Level Volume control(with LED indicator)

Adjust the mixing level of each channel.
The LED on the knob lights on to see and operate the knob easily in a dark place
when the LIGHT switch on the left panel (     ) turns on.

(CAUTION) The volume controls of the CH 3 and 4ch perform 
                 the different functions when the L/C/R/MS select 
                 switches are set to the MS position.

                 CH 3 volume control adjusts the volume, gain.
                 CH 4 volume control adjusts the soundscape.

3

4

When setting to MS

volume

extent

20/300 Low Cut Frequency Adjust Control

Used for adjusting the cut-off frequency to cut the low frequency noise of 20Hz - 300Hz

such as wind noises.

Adjust it while monitoring by headphones.

1kHz Oscillator/Battery Check Switch

1 kHz       : The 1 kHz oscillator is turned on. The 1 kHz reference signal is output to

                 the MAS OUT and SUB OUT connectors.

                              <Battery Check>  

(Battery)        : When the switch is turned to the       

                      side, the indication of the VU/PEAK 

                      meter of the L is replaced by battery

                      residual quantity indication.

                      The indication of the residual quantity

                      is shown in the right figure. 

1              2       3               6 7                 12H.

   Hours

7.8V           8.2V           8.9V                  9.8V                 12.2V

   Voltage

lights on

 blink

(wink)

Meter

L E D

Содержание FS-40X

Страница 1: ...Volume1 1st edition Ver 1 0 Operating Instructions Before operating the system please read this manual thoroughly and keep it for future reference FS 40X 4 ch Field Mixer TM...

Страница 2: ...ratus To reduce the risk of overheating re electric shock injury or malfunction Failing to do so may cause overheating re electric shock injury or malfunction 02 Contact the NIPROS Service center or t...

Страница 3: ...ight side 4 Table of Contents Block Diagram Outside View and Dimensions Speci cations Use 12 Power Supply Input Signal Setting Output Signal Connection and Setting Output Level Adjustment Input Level...

Страница 4: ...nnected LINE When a line level 0 dB signal source is connected AB12 When a A B 12 V microphone is connected Ex SENNHEISER MKH416T etc FS 40X A type female FS 40X B type male Input Select Switches 1 2...

Страница 5: ...depending on each function LIGHT Switch MS IN 3 4 Connector XLR 5 pin Used for the stereo signals input The signals are input to the channel 3 and 4 NOTE Do not connect to the MS connector and to the...

Страница 6: ...nges to ORANGE Adjusts the input signal volume level to input it with the apprppriate level MIC The input signal level of 70dB min up to 30 dB max is supported LINE The input signal level of 30dB min...

Страница 7: ...ume controls of the CH 3 and 4ch perform the di erent functions when the L C R MS select switches are set to the MS position CH 3 volume control adjusts the volume gain CH 4 volume control adjusts the...

Страница 8: ...signal to the 6 3 headphone jack on the main panel and the 3 5 mini jack on the right side output panel to monitor headphones HEADPHONE MONITOR 6 3 Jack Used for output to monitor the signal set by th...

Страница 9: ...he frequency of the signal to equalize free in the range of 250Hz 8kHz The equalizing level control is provided for each equalizer and adjusts the level of the signal set by the frequency control in t...

Страница 10: ...CT switch is set to the MIX position the 3 L OUT connector outputs the L channel signal and 4 R OUT connector outputs R channel signal and when the DIRECT position the 3 L OUT connector outputs the 3...

Страница 11: ...sed to monitor the MAS OUT signal by the headphone with the 3 5 mini plug It can be used at the same time with the headphone connected to the 6 3 jack on the main panel MAS OUT 4 0 20 60 dB Select Swi...

Страница 12: ...Notice Surely con rm that the battery case is locked side where battery is seen Press the BATT RELEASE button and get the battery case out Install eight size AA battery dry cells in the right directi...

Страница 13: ...WER LED lights on 2 When the battery chech switch is turned on to the battery side the L BATT meter indicates the battery residual quantity If the needle of the meter reads the most right domain of th...

Страница 14: ...hone AB12 When connecting a A B 12 V type microphone ex SENNHEISER MKH416T etc D MIC When connecting a dynamic microphone that does not need a power supply BATTERY CASE Set the input select switch Inp...

Страница 15: ...ect switches to the appropriate position according to the input level of the recorder etc connected MAS OUT 1 L and 2 R can be set to 4 0 20 or 60dB and SUB OUT 3 L and 4 R can be set to 20 and 60dB 4...

Страница 16: ...t the HEADPHONE MONITOR select switch on the right side of the main panel front to the appropriate position L R or other and turn the HEADPHONE MONITOR LEVEL volume control to a little upper position...

Страница 17: ...0 VU PK BATT 1 2 3 20 107 5 3 1 0 V U 30 12 20 40 1 2 3 20 107 5 3 1 0 NIPPON VIDEO SYSTEM CO LTD VU PEAK PROTECH FS 305 0 60 VU PK BATT 0 20 After adjusting turn the 1 kHz switch o 20 12 30 40 60 0 V...

Страница 18: ...the input connector pressed down turn the LINE MIC volume control to adjust the input level to the appropriate volume Set the L C R channel select switch to any position Adjust the input level to the...

Страница 19: ...the range of 12dB from 12dB by the LEVEL volume control provided for each input channel 1 Turn on the ON OFF switch of a channel 2 Turn the LEVEL volume control fully up to the 12dB position Turn the...

Страница 20: ...20 Block Diagram 4 ch Field Mixer FS 40X FS 40X XLR 4P...

Страница 21: ...KHz 12dB 12dB ON OFF FRQ LEVEL 4 250Hz 8KHz 12dB 12dB ON OFF FRQ LEVEL FRQ LEVEL FRQ LEVEL PROTECH NIPPON VIDEO SYSTEMCO LTD MADE IN JAPAN R FS 40X 1 GND 4 12V 1 2 3 4 5 1 GND 2 HOT 3 COLD 4 HOT 5 COL...

Страница 22: ...ttery 8x LR 6 with Size AA battery case supplied Sony Li ion battery pack using the Battery adaptor BKW L601 Optional DC Powewr DC 12V IN 1x XLR 4 pin male DC 9 V to 18 V Max 0 5 A Power Consumption a...

Страница 23: ...FS 40X Operating Instructions TM...

Отзывы: