NIPROS FS-40X Скачать руководство пользователя страница 14

4 ch Field Mixer FS-40X

Use

14

Input Signal Setting

Before connecting the input signals, select and set the input select switches.

Select the input connector to which the input signal will be input according to the mixing channel

and the output connector.

■Input Select Switch Setting and Input Signal Connection

LINE   : When connecting the LINE level signal.

P48    : When connecting a phantom 48 V condenser microphone.

AB12  : When connecting a A-B 12 V type microphone. 

            (ex. SENNHEISER MKH416T, etc.)

D-MIC : When connecting a dynamic microphone

            that does not need a power supply.

BATTERY CASE

Set the input select switch

Input connector

Input signal

XLR 3-pin  female

2PIN:HOT

1PIN:GND

3PIN:COLD

1PIN:GND

2PIN:HOT

3PIN:COLD

XLR 3-pin  male

1. Set the input select switch according to the input signal.

2. After setting the input select switches, connect the input signals to each of the input connectors

    by the XLR 3-pin cable.

Input select switches

Input connectors (XLR 3-pin)

Input Connector Pinassignment

FS-40X A type

FS-40X B type

Содержание FS-40X

Страница 1: ...Volume1 1st edition Ver 1 0 Operating Instructions Before operating the system please read this manual thoroughly and keep it for future reference FS 40X 4 ch Field Mixer TM...

Страница 2: ...ratus To reduce the risk of overheating re electric shock injury or malfunction Failing to do so may cause overheating re electric shock injury or malfunction 02 Contact the NIPROS Service center or t...

Страница 3: ...ight side 4 Table of Contents Block Diagram Outside View and Dimensions Speci cations Use 12 Power Supply Input Signal Setting Output Signal Connection and Setting Output Level Adjustment Input Level...

Страница 4: ...nnected LINE When a line level 0 dB signal source is connected AB12 When a A B 12 V microphone is connected Ex SENNHEISER MKH416T etc FS 40X A type female FS 40X B type male Input Select Switches 1 2...

Страница 5: ...depending on each function LIGHT Switch MS IN 3 4 Connector XLR 5 pin Used for the stereo signals input The signals are input to the channel 3 and 4 NOTE Do not connect to the MS connector and to the...

Страница 6: ...nges to ORANGE Adjusts the input signal volume level to input it with the apprppriate level MIC The input signal level of 70dB min up to 30 dB max is supported LINE The input signal level of 30dB min...

Страница 7: ...ume controls of the CH 3 and 4ch perform the di erent functions when the L C R MS select switches are set to the MS position CH 3 volume control adjusts the volume gain CH 4 volume control adjusts the...

Страница 8: ...signal to the 6 3 headphone jack on the main panel and the 3 5 mini jack on the right side output panel to monitor headphones HEADPHONE MONITOR 6 3 Jack Used for output to monitor the signal set by th...

Страница 9: ...he frequency of the signal to equalize free in the range of 250Hz 8kHz The equalizing level control is provided for each equalizer and adjusts the level of the signal set by the frequency control in t...

Страница 10: ...CT switch is set to the MIX position the 3 L OUT connector outputs the L channel signal and 4 R OUT connector outputs R channel signal and when the DIRECT position the 3 L OUT connector outputs the 3...

Страница 11: ...sed to monitor the MAS OUT signal by the headphone with the 3 5 mini plug It can be used at the same time with the headphone connected to the 6 3 jack on the main panel MAS OUT 4 0 20 60 dB Select Swi...

Страница 12: ...Notice Surely con rm that the battery case is locked side where battery is seen Press the BATT RELEASE button and get the battery case out Install eight size AA battery dry cells in the right directi...

Страница 13: ...WER LED lights on 2 When the battery chech switch is turned on to the battery side the L BATT meter indicates the battery residual quantity If the needle of the meter reads the most right domain of th...

Страница 14: ...hone AB12 When connecting a A B 12 V type microphone ex SENNHEISER MKH416T etc D MIC When connecting a dynamic microphone that does not need a power supply BATTERY CASE Set the input select switch Inp...

Страница 15: ...ect switches to the appropriate position according to the input level of the recorder etc connected MAS OUT 1 L and 2 R can be set to 4 0 20 or 60dB and SUB OUT 3 L and 4 R can be set to 20 and 60dB 4...

Страница 16: ...t the HEADPHONE MONITOR select switch on the right side of the main panel front to the appropriate position L R or other and turn the HEADPHONE MONITOR LEVEL volume control to a little upper position...

Страница 17: ...0 VU PK BATT 1 2 3 20 107 5 3 1 0 V U 30 12 20 40 1 2 3 20 107 5 3 1 0 NIPPON VIDEO SYSTEM CO LTD VU PEAK PROTECH FS 305 0 60 VU PK BATT 0 20 After adjusting turn the 1 kHz switch o 20 12 30 40 60 0 V...

Страница 18: ...the input connector pressed down turn the LINE MIC volume control to adjust the input level to the appropriate volume Set the L C R channel select switch to any position Adjust the input level to the...

Страница 19: ...the range of 12dB from 12dB by the LEVEL volume control provided for each input channel 1 Turn on the ON OFF switch of a channel 2 Turn the LEVEL volume control fully up to the 12dB position Turn the...

Страница 20: ...20 Block Diagram 4 ch Field Mixer FS 40X FS 40X XLR 4P...

Страница 21: ...KHz 12dB 12dB ON OFF FRQ LEVEL 4 250Hz 8KHz 12dB 12dB ON OFF FRQ LEVEL FRQ LEVEL FRQ LEVEL PROTECH NIPPON VIDEO SYSTEMCO LTD MADE IN JAPAN R FS 40X 1 GND 4 12V 1 2 3 4 5 1 GND 2 HOT 3 COLD 4 HOT 5 COL...

Страница 22: ...ttery 8x LR 6 with Size AA battery case supplied Sony Li ion battery pack using the Battery adaptor BKW L601 Optional DC Powewr DC 12V IN 1x XLR 4 pin male DC 9 V to 18 V Max 0 5 A Power Consumption a...

Страница 23: ...FS 40X Operating Instructions TM...

Отзывы: