NIPROS FS-40X Скачать руководство пользователя страница 6

06

4 ch Field Mixer FS-40X

Parts Names and Funcctions

Maint panel (Front)

POWER

INT OFF EXT

METER

SELECT

VU

PK

R / PFL

L / BATT

L

R

FIELD  MIXER

LEVEL

LMT

PFL

L

L+R

VU

PK

MS

0

L

R

R

/

LMT

PFL

LMT

PFL

LMT

PFL

0

0

0

MS

EQ (Equalizer) LED

PK/D LED  Over level/Direct input/Over level Indicator

MIC/LINE Input Level Volume Control

LMT/PFL Switch  Hyper Limiter/Pre Fader Listen Switch

The equalizer LED on the main panel lights on to YELLOW when the equalizer switch turns on

.

When an input level exceeded a level every each ch at the moment, the LED turns on.

It shows that a set point of an input level is high or the master volume level is not appropriate.

  PK=RED : When the OUT SELECT switch is set to the MIX position, and when the 

                input signal exceeds the level, the LED lights on to RED.

  D=GREEN : When the OUT SELECT switch is set to the DIRECT position, the LED

                   lights on to GREEN.

  D=Orange : When the OUT SELECT switch is set to the DIRECT position, and when 

                   the input signal exceeds the level, the LED light changes to ORANGE.

Adjusts the input signal volume level to input it with the apprppriate level.

  MIC : The input signal level of -70dB min. up to -30 dB max. is supported.

  LINE : The input signal level of -30dB min. up to +4 dB max. is supported.

It can match the audio signals different in the level from the different microphone in the

sensitivity or from the different audio source different in the level with the same level.

Each input CH is provided with a hyper limiter circuit independently and the switch that can

turn on or off the hyper limiter circuit of each CH independently. 

When the switch is set to the LMT side, a hyper limiter circuit turns on and functions.

PFL Function : 

While pressing the switch down to the PFL position, PFL function operates.

And a level of the signal just before the master volume, just before fader circuit, is displayed

by the right meter , and only the sound of the signal is output to headphones.

(NOTE)When using the Hyper Limiter, turn it on after at first adjusting and setting the level 

           by the trim volume and the master volume in the limiter switch OFF

(Caution) When the CH master volume is MIN(   ) even if the the sound is output by the PFL function,

               the sound is not mixed and output.

Содержание FS-40X

Страница 1: ...Volume1 1st edition Ver 1 0 Operating Instructions Before operating the system please read this manual thoroughly and keep it for future reference FS 40X 4 ch Field Mixer TM...

Страница 2: ...ratus To reduce the risk of overheating re electric shock injury or malfunction Failing to do so may cause overheating re electric shock injury or malfunction 02 Contact the NIPROS Service center or t...

Страница 3: ...ight side 4 Table of Contents Block Diagram Outside View and Dimensions Speci cations Use 12 Power Supply Input Signal Setting Output Signal Connection and Setting Output Level Adjustment Input Level...

Страница 4: ...nnected LINE When a line level 0 dB signal source is connected AB12 When a A B 12 V microphone is connected Ex SENNHEISER MKH416T etc FS 40X A type female FS 40X B type male Input Select Switches 1 2...

Страница 5: ...depending on each function LIGHT Switch MS IN 3 4 Connector XLR 5 pin Used for the stereo signals input The signals are input to the channel 3 and 4 NOTE Do not connect to the MS connector and to the...

Страница 6: ...nges to ORANGE Adjusts the input signal volume level to input it with the apprppriate level MIC The input signal level of 70dB min up to 30 dB max is supported LINE The input signal level of 30dB min...

Страница 7: ...ume controls of the CH 3 and 4ch perform the di erent functions when the L C R MS select switches are set to the MS position CH 3 volume control adjusts the volume gain CH 4 volume control adjusts the...

Страница 8: ...signal to the 6 3 headphone jack on the main panel and the 3 5 mini jack on the right side output panel to monitor headphones HEADPHONE MONITOR 6 3 Jack Used for output to monitor the signal set by th...

Страница 9: ...he frequency of the signal to equalize free in the range of 250Hz 8kHz The equalizing level control is provided for each equalizer and adjusts the level of the signal set by the frequency control in t...

Страница 10: ...CT switch is set to the MIX position the 3 L OUT connector outputs the L channel signal and 4 R OUT connector outputs R channel signal and when the DIRECT position the 3 L OUT connector outputs the 3...

Страница 11: ...sed to monitor the MAS OUT signal by the headphone with the 3 5 mini plug It can be used at the same time with the headphone connected to the 6 3 jack on the main panel MAS OUT 4 0 20 60 dB Select Swi...

Страница 12: ...Notice Surely con rm that the battery case is locked side where battery is seen Press the BATT RELEASE button and get the battery case out Install eight size AA battery dry cells in the right directi...

Страница 13: ...WER LED lights on 2 When the battery chech switch is turned on to the battery side the L BATT meter indicates the battery residual quantity If the needle of the meter reads the most right domain of th...

Страница 14: ...hone AB12 When connecting a A B 12 V type microphone ex SENNHEISER MKH416T etc D MIC When connecting a dynamic microphone that does not need a power supply BATTERY CASE Set the input select switch Inp...

Страница 15: ...ect switches to the appropriate position according to the input level of the recorder etc connected MAS OUT 1 L and 2 R can be set to 4 0 20 or 60dB and SUB OUT 3 L and 4 R can be set to 20 and 60dB 4...

Страница 16: ...t the HEADPHONE MONITOR select switch on the right side of the main panel front to the appropriate position L R or other and turn the HEADPHONE MONITOR LEVEL volume control to a little upper position...

Страница 17: ...0 VU PK BATT 1 2 3 20 107 5 3 1 0 V U 30 12 20 40 1 2 3 20 107 5 3 1 0 NIPPON VIDEO SYSTEM CO LTD VU PEAK PROTECH FS 305 0 60 VU PK BATT 0 20 After adjusting turn the 1 kHz switch o 20 12 30 40 60 0 V...

Страница 18: ...the input connector pressed down turn the LINE MIC volume control to adjust the input level to the appropriate volume Set the L C R channel select switch to any position Adjust the input level to the...

Страница 19: ...the range of 12dB from 12dB by the LEVEL volume control provided for each input channel 1 Turn on the ON OFF switch of a channel 2 Turn the LEVEL volume control fully up to the 12dB position Turn the...

Страница 20: ...20 Block Diagram 4 ch Field Mixer FS 40X FS 40X XLR 4P...

Страница 21: ...KHz 12dB 12dB ON OFF FRQ LEVEL 4 250Hz 8KHz 12dB 12dB ON OFF FRQ LEVEL FRQ LEVEL FRQ LEVEL PROTECH NIPPON VIDEO SYSTEMCO LTD MADE IN JAPAN R FS 40X 1 GND 4 12V 1 2 3 4 5 1 GND 2 HOT 3 COLD 4 HOT 5 COL...

Страница 22: ...ttery 8x LR 6 with Size AA battery case supplied Sony Li ion battery pack using the Battery adaptor BKW L601 Optional DC Powewr DC 12V IN 1x XLR 4 pin male DC 9 V to 18 V Max 0 5 A Power Consumption a...

Страница 23: ...FS 40X Operating Instructions TM...