Tools Required
A Phillips screwdriver
Locating the Appliance
Your new electric fireplace may be installed virtually anywhere in
your home. However, when choosing a location, ensure that the
general instructions for safety are followed.
For best results, install out of direct sunlight, water or very damp
air.
Power supply service must be installed within proximity of
electric fireplace prior to finishing avoiding reconstruction.
•
•
Minimum Clearance to Combustibles
sides............................0 inch
Floor............................0 inch
Back.............................0 inch
Top (shelf or TV)......8 inch min
Front..........................36 inch
WARNING! Risk of Fire!
Keep electrical cords, drapery,
furnishings or other combustibles
at least 3ft. (0.9 m) from the front
of the electric fireplace.
Electrical Supply Circuit Requirements
P l a n t h e l o c a t i o n o f t h e
appliance so that it will have
adequate electric power. A 15
AMP, 60Hz circuit is required
f o r 1 2 0 V i n s t a l l a t i o n . T h e
appliance should ideally be
located close to a suitable
main socket to enable power
connection.
The power cord is 6ft long and
locates on the right side of the
unit. If the cord is found not
•
•
Grounding Pin
Adapter
Metal Grounding
Screw
7