6.4 Advanced Info - Technicians Only
Select Advanced Info. from the Main Menu to display a screen that requires a password
(see Figure 6.8).
YES=<ENT> NO=<ESC>
Password: 0000
Figure 6.8 Advanced Info. Login
Type in the correct password and press the ENTER key to access the following information:
1.Alarm Message
2.Temperature
3.STD NO.
4.Version
5.Communication Data
Screens can be scrolled manually by pressing the UP/DOWN keys. Pressing the ENTER
key gives access to submenu. Press the ESC key to return to the Main Menu.
NOTE:
The default password of Solis-2.5K-2G is (0010
)
6.4.1 Alarm Message
The display shows 10 latest alarm messages (see Figure 6.9). Screens can be scrolled
manually by pressing the UP/ DOWN keys. Press the ESC key to return to the previous
menu.
Alarm0: OV-G-V
Time: 27-11 Data: 7171
Figure 6.9 Alarm Message
6.4.3 STD NO.
The screen shows the reference standard of Solis-2.5K-2G (see Figure 6.11).
Standard: AS4777
Figure 6.11 Standard of the Inverter
6.4.4 Version
The screen shows the model version and the software version of Solis-2.5K-2G (see Figure 6.12).
Model: 07
Software Version: 8E06
Figure 6.12 Model Version and Software Version
6.4.5 Communication Data
The screen shows the internal data of Solis-2.5K-2G (see Figure 6.13), which is for service
technicians only.
01-05: 01 25 E4 9D AA
06-10: C2 B5 E4 9D 55
Figure 6.13 Communication Data
6.5 Advanced Settings - Technicians Only
Select Advanced Settings from the Main Menu to display a screen that requires a password.
Type in the correct password (refer to Section 6.4 if you do not know the password) and
press the ENTER key to access the following options:
1.Select Standard
2.Grid ON/OFF
3.New Password
.21.
.22.
6. Operation
6. Operation
6.4.2 Temperature
The screen shows the power module temperature of Solis-2.5K-2G (see Figure 6.10).
Figure 6.10 Temperature of the Inverter
Temperature
046.6
℃
NOTE:
Access to this area is for fully qualified and accredited technicians only.
Unauthorized access to these areas may void the warranty.
NOTE:
Access to this area is for fully qualified and accredited technicians only.
Unauthorized access to these areas may void the warranty.