background image

5

Arsenic (abbreviated AS) is a naturally occurring contaminate found in many

ground waters. Arsenic is water that has no color, taste or oder. It must be

measured by a lab test. Public water utilities must have their water tested

for arsenic. You can get the results from your own water utility. If you have

your own well, you can have the water tested. The local health department

or the state environmental health agency can provide a list of certified labs.

The cost is typically $15 to $30. Information about arsenic in water can be

found on the internet at the US Environmental Protection Agency website:

www.epa.gov/safewater/arsenic.html.

There are two forms of arsenic: pentavalent arsenic (also called As(V),

As(+5), and arsenate) and trivalent arsenic (also called As(III), As(+3), and

arsenite). In well water, arsenic may be pentavalent, trivalent, or a combina-

tion of both. Special sampling procedures are needed for a lab to determine

what type and how much of each type of arsenic is in the water. Check with

the labs in your area to see if they can provide this type of service.

Reverse Osmosis (RO) water treatment systems do not remove trivalent ar-

senic from water very well. RO systems are very effective at removing pen-

tavalent arsenic. A free chlorine residual will rapidly convert trivalent arsenic

to pentavalent arsenic. Other water treatment chemicals such as ozone and

potassium permanganate will also change trivalent arsenic to pentavalent

arsenic. A combined chlorine residual (also called chloramine) may not con-

vert all the trivalent arsenic. If you get your water from a public water utility,

contact the utility to find out if free chlorine or combined chlorine is used in

the water system.

The Nimbus Sierra system is designed to remove pentavalent arsenic. It will

not convert trivalent arsenic to pentavalent arsenic. The system was tested

in a lab. Under those conditions, the system reduced 0.30 mg/L (ppm) pen-

tavalent arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water)

or less. The performance of the system may be different at your installation.

Have the treated water tested for arsenic to check if the system is working

properly.

The RO component of the Nimbus Sierra system must be replaced yearly to

ensure the system will continue to remove pentavalent arsenic. The compo-

nent identification and location where you can purchase this component are

listed in this installation manual.

E

OWNER'S MANUAL

Arsenic Facts

Содержание Sierra

Страница 1: ...1 REVERSE OSMOSIS DRINKING WATER SYSTEM Owner sManual InstallationGuide 41840 McAlby Court Suite A CA Murrieta 92562 800 451 9343 Email sierra nimbuswater com ...

Страница 2: ...r intervals The chart below gives a general replacement timetable For more accurate membrane filter replacement intervals the system should be tested for TDS by an authorized Nimbus dealer Instructions for cartridge replacement can be found in Section 10 of the Installation Guide Any significant change in performance of the system should be investigated promptly to avoid secondary damage or deteri...

Страница 3: ...ng and service This reverse osmosis system contains a replaceable component critical to the effiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance Use of non Sierra replacement parts will invalidate the warranty as set forth in Section F of ...

Страница 4: ...ncentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permis sible limit for water leaving the system as specified in NSF ANSI 58 This system has been tested for the treatment of water containing pentavalent arsenic also known as As V As 5 or arsenate at concentrations of 0 30 mg L or less This system reduces pentavalent arsen...

Страница 5: ... remove trivalent ar senic from water very well RO systems are very effective at removing pen tavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not con vert al...

Страница 6: ...yondthecontrolofthe Manufacturerarenotcoveredbythiswarranty IncidentalandConsequentialDamages TheManufacturerdoesnotassumeresponsibilityforpaymentofincidentalandconsequential damagesasaresultofthefailureofthisunittocomplywithexpressorimpliedwarranties suchaslosttime inconvenience damageto personalproperty lossofrevenue commerciallosses postage travel telephoneexpenditures orotherlossesofthisnature...

Страница 7: ...ithstandardsink plumbingandproperuseofcommonhandandpowertools Improperlyinstalledsystemscouldresult inwaterdamageduetoleaksorflooding Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequate disinfection before or after the system 1 A Product water storage tank I Product water tubing 3 8 blue B Tank shut off valve J Reverse osmosis membrane filter C Tank tubing 3 8 white K C...

Страница 8: ...fwarninglabel Self tapping mounting screws 2 Flatrubberwasher Grayrubbercone Faucet Kit not shown Tubing notshown 6 white 3 8 tubing 4 blue 3 8 tubing 4 green 1 4 tubing 4 yellow 1 4 tubing F The feed water connection assembly supplied with the Sierra system includes components which represent the most common under sink plumbing connections currently in use within the United States If these compon...

Страница 9: ...ireanopenendwrench pliers orlong reachfaucetwrench Proceedtostep4 OptionB Toinstallthefeedadapterattheanglestop valve disconnectthefeedlineattheanglestop valve Thiswillusuallyrequireawrenchorpliers Withthisendofthewaterlinefree proceedtostep 4 4 Takethe1 4 feedconnectorvalvefromthepartskitandinstallitintothebrassfeedconnector adapter Useacrescentwrenchoropen endwrenchtotightenthevalveintotheadapte...

Страница 10: ...le in the drain assembly 5 Tightenthesaddleboltsevenlyonbothsidesuntilthesaddlegripsthepipesnugly donot overtighten Fig 4 Inadditiontocommonhandtools thefollowingtoolsarerequiredfordrillingthroughthemost commonsinkmaterials 1 4 masonrydrillbit 1 porcelain cutter 1 hole saw Hole saw adapter 7 8 chassispunch Centerpunch Hint Specialcareshouldbetakenwhendrillingthefaucethole Acleanholecan becutinasho...

Страница 11: ...nk and wipe the area clean Be sure all metal chips are removed as they can stainporcelainveryquickly Tile Sink or Counter 1 Followprocedures1 3underEnamel Porcelain CastIronSinkprocedures 2 Withthegentleuseofthecenterpunchandhammer breakuptheceramicdisktotheextent necessarytoremoveit Removetheceramicdisk 3 Use the 1 hole saw or wood drill to continue the hole through the wooden support Clear awayt...

Страница 12: ... Inserttubingandfaucetassemblydownthroughthe sink hole 8 Positionthefaucettothedesiredhandleorientation Sliptheslottedwasherbetweenthewhiteplasticspacer andthesink Securelyhandtightenthemountingnut Hint The airgap tubing connection is located under the faucet handle By orientingtheair gapfromtheunderside of the sink your faucet handle should be correctlyoriented 9 Connectthewhite3 8 tubingtothedra...

Страница 13: ...eunittoberemovedfromtheinstalledlocationforservicing Cutofftheexcess andfirmlyinsertthetubingintothecorrespondingyellowdrainconnectionlocatedonthemani fold 5 Extendthe3 8 bluetubingfromthefaucetunittothemanifold Leaveenoughslackinthe tubingtoallowtheunittoberemovedfromtheinstalledlocationforservicing Cutofftheexcess andfirmlyinsertthetubingintothecorrespondingblueproductwaterconnectionlocatedonthe...

Страница 14: ...ent inordertoensuretankinternalcleanliness Also thecarbonfiltercartridge willreleaseasmallamountofcarbonfinesduringthefirsttankfulofflow Thisflushingprocedure willallowanysanitizerorcarbonfinestopassfromthesystem 2 Initialtankfillingwilltakeapproximatelytwoandonehalfhours basedonaveragefeed pressure Whenthetankisfull thewaterpressurewillhaverisentothepointwheretheauto maticshut offvalveinsidethema...

Страница 15: ...properly 4 Alltubingconnections especiallypush inquickconnections arefullyinserted 5 Tubingconnectedbetweenthefaucetandthedrainsaddlefitting thefittingattachedtothesink drainpipe runs downhill tothedrain Thereshouldbenoloopsorplaceswherewaterwouldnot flowouttothedrain 6 Feedandtankvalvesareopen 7 Withinonetotwohoursafterinitialapplicationofwaterpressure checkagainforleaksespecially atthetank fauce...

Страница 16: ...nnectorsuntilitsnapsintoplaceproperly 7 Turnonfeedwatershut offvalve 8 Turnontankshut offvalve Observesystemforanyleaks especiallyatnewlyreplaced cartridge 9 Closedispensingfaucetafterwaterstopsrunning 10 Ifreplacedcartridgewasapostcarbonoramembranefilter thesystemshouldbeflushedat leastonceasdescribedaboveunderSection9 TankSanitizing Tanksanitizingshouldbedoneeverytwelvemonthsaspartoftheregularsy...

Страница 17: ...17 NimbusWaterSystems2003 PN103257 ...