Nimbus Water Systems Sierra Скачать руководство пользователя страница 15

15

1. Sierra unit and tank are located where they will not be subject to physical impacts or rough contact

by heavy objects.

2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI.

3. Ensure the plastic retainer clips are fully engaged.  The slide locks must snap into place in the slots.

If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted

into the connectors.  Press top or bottom of cartridge to engage connectors until it snaps into place

properly.

4. All tubing connections, especially push-in quick connections, are fully inserted.

5. Tubing connected between the faucet and the drain saddle fitting (the fitting attached to the sink

drain pipe) runs "downhill" to the drain.  There should be no loops or places where water would not

flow out to the drain.

6. Feed and tank valves are open.

7. Within one to two hours after initial application of water pressure, check again for leaks especially

at the tank, faucet tubing and connectors.  These parts will not see full pressure until approximately

2 hours after the system is activated.

8. Flush three tankfuls of product water to drain.  If a chlorine scent persists, repeat flushing

procedure in Section 8.

INSTALLATION

Check List

9

Содержание Sierra

Страница 1: ...1 REVERSE OSMOSIS DRINKING WATER SYSTEM Owner sManual InstallationGuide 41840 McAlby Court Suite A CA Murrieta 92562 800 451 9343 Email sierra nimbuswater com ...

Страница 2: ...r intervals The chart below gives a general replacement timetable For more accurate membrane filter replacement intervals the system should be tested for TDS by an authorized Nimbus dealer Instructions for cartridge replacement can be found in Section 10 of the Installation Guide Any significant change in performance of the system should be investigated promptly to avoid secondary damage or deteri...

Страница 3: ...ng and service This reverse osmosis system contains a replaceable component critical to the effiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance Use of non Sierra replacement parts will invalidate the warranty as set forth in Section F of ...

Страница 4: ...ncentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permis sible limit for water leaving the system as specified in NSF ANSI 58 This system has been tested for the treatment of water containing pentavalent arsenic also known as As V As 5 or arsenate at concentrations of 0 30 mg L or less This system reduces pentavalent arsen...

Страница 5: ... remove trivalent ar senic from water very well RO systems are very effective at removing pen tavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not con vert al...

Страница 6: ...yondthecontrolofthe Manufacturerarenotcoveredbythiswarranty IncidentalandConsequentialDamages TheManufacturerdoesnotassumeresponsibilityforpaymentofincidentalandconsequential damagesasaresultofthefailureofthisunittocomplywithexpressorimpliedwarranties suchaslosttime inconvenience damageto personalproperty lossofrevenue commerciallosses postage travel telephoneexpenditures orotherlossesofthisnature...

Страница 7: ...ithstandardsink plumbingandproperuseofcommonhandandpowertools Improperlyinstalledsystemscouldresult inwaterdamageduetoleaksorflooding Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequate disinfection before or after the system 1 A Product water storage tank I Product water tubing 3 8 blue B Tank shut off valve J Reverse osmosis membrane filter C Tank tubing 3 8 white K C...

Страница 8: ...fwarninglabel Self tapping mounting screws 2 Flatrubberwasher Grayrubbercone Faucet Kit not shown Tubing notshown 6 white 3 8 tubing 4 blue 3 8 tubing 4 green 1 4 tubing 4 yellow 1 4 tubing F The feed water connection assembly supplied with the Sierra system includes components which represent the most common under sink plumbing connections currently in use within the United States If these compon...

Страница 9: ...ireanopenendwrench pliers orlong reachfaucetwrench Proceedtostep4 OptionB Toinstallthefeedadapterattheanglestop valve disconnectthefeedlineattheanglestop valve Thiswillusuallyrequireawrenchorpliers Withthisendofthewaterlinefree proceedtostep 4 4 Takethe1 4 feedconnectorvalvefromthepartskitandinstallitintothebrassfeedconnector adapter Useacrescentwrenchoropen endwrenchtotightenthevalveintotheadapte...

Страница 10: ...le in the drain assembly 5 Tightenthesaddleboltsevenlyonbothsidesuntilthesaddlegripsthepipesnugly donot overtighten Fig 4 Inadditiontocommonhandtools thefollowingtoolsarerequiredfordrillingthroughthemost commonsinkmaterials 1 4 masonrydrillbit 1 porcelain cutter 1 hole saw Hole saw adapter 7 8 chassispunch Centerpunch Hint Specialcareshouldbetakenwhendrillingthefaucethole Acleanholecan becutinasho...

Страница 11: ...nk and wipe the area clean Be sure all metal chips are removed as they can stainporcelainveryquickly Tile Sink or Counter 1 Followprocedures1 3underEnamel Porcelain CastIronSinkprocedures 2 Withthegentleuseofthecenterpunchandhammer breakuptheceramicdisktotheextent necessarytoremoveit Removetheceramicdisk 3 Use the 1 hole saw or wood drill to continue the hole through the wooden support Clear awayt...

Страница 12: ... Inserttubingandfaucetassemblydownthroughthe sink hole 8 Positionthefaucettothedesiredhandleorientation Sliptheslottedwasherbetweenthewhiteplasticspacer andthesink Securelyhandtightenthemountingnut Hint The airgap tubing connection is located under the faucet handle By orientingtheair gapfromtheunderside of the sink your faucet handle should be correctlyoriented 9 Connectthewhite3 8 tubingtothedra...

Страница 13: ...eunittoberemovedfromtheinstalledlocationforservicing Cutofftheexcess andfirmlyinsertthetubingintothecorrespondingyellowdrainconnectionlocatedonthemani fold 5 Extendthe3 8 bluetubingfromthefaucetunittothemanifold Leaveenoughslackinthe tubingtoallowtheunittoberemovedfromtheinstalledlocationforservicing Cutofftheexcess andfirmlyinsertthetubingintothecorrespondingblueproductwaterconnectionlocatedonthe...

Страница 14: ...ent inordertoensuretankinternalcleanliness Also thecarbonfiltercartridge willreleaseasmallamountofcarbonfinesduringthefirsttankfulofflow Thisflushingprocedure willallowanysanitizerorcarbonfinestopassfromthesystem 2 Initialtankfillingwilltakeapproximatelytwoandonehalfhours basedonaveragefeed pressure Whenthetankisfull thewaterpressurewillhaverisentothepointwheretheauto maticshut offvalveinsidethema...

Страница 15: ...properly 4 Alltubingconnections especiallypush inquickconnections arefullyinserted 5 Tubingconnectedbetweenthefaucetandthedrainsaddlefitting thefittingattachedtothesink drainpipe runs downhill tothedrain Thereshouldbenoloopsorplaceswherewaterwouldnot flowouttothedrain 6 Feedandtankvalvesareopen 7 Withinonetotwohoursafterinitialapplicationofwaterpressure checkagainforleaksespecially atthetank fauce...

Страница 16: ...nnectorsuntilitsnapsintoplaceproperly 7 Turnonfeedwatershut offvalve 8 Turnontankshut offvalve Observesystemforanyleaks especiallyatnewlyreplaced cartridge 9 Closedispensingfaucetafterwaterstopsrunning 10 Ifreplacedcartridgewasapostcarbonoramembranefilter thesystemshouldbeflushedat leastonceasdescribedaboveunderSection9 TankSanitizing Tanksanitizingshouldbedoneeverytwelvemonthsaspartoftheregularsy...

Страница 17: ...17 NimbusWaterSystems2003 PN103257 ...