4

42445 Avenida Alavardo, Temecula, CA 92590 

(800) 451-9343,  www.nimbuswater.com

Warranty

ascade

C

This Limited Warranty extends to the original purchaser of the system only. This warranty covers all Manufacturer-supplied items only that 

prove to be defective in material, workmanship or factory preparation. This warranty covers parts only; all labor is excluded from this war-

ranty, including, but not limited to, services related to the removal, replacement, installation, adjustment, maintenance and/or repair of 

the unit or its components items. excludes all non-Manufacturer labor required for any servicing of the unit, including, but not limited to, 

servicing related to installation, adjustment, maintenance and repair of the unit. This warranty applies only for the first full calendar year 

from date of purchase. The following items are excluded from this warranty: membranes, filters, O-rings, and all other parts or compo-

nents that require regular replacement as a result of ordinary usage.  

Disclaimers

: This Limited Warranty applies only if the system is installed, used and maintained in compliance with all instructions and 

requirements enclosed with the system. This warranty will be void for failure to observe the following conditions: 

1.  The system is to be used with potable water from a municipal water system.

2.  Feed water pressure to the unit is no less than 40 PSI and no greater than 80 PSI.

3.  The system is to be used on water supplies with chlorine concentrations of 1.0 mg/L (ppm) or less.

4.  Feed water temperature to the unit must be no less than 40°F and no more than 100°F.

5.  Total dissolved solids in feed water must be less than 2,000 mg/L (ppm).

6.  Feed water must have a pH between 4 and 8.

7.  Turbidity must be less than 1.0 NTU.

8.  SDI must be less than 5.

9.  Feed water must be completely free of iron, manganese or hydrogen sulfide.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

The Manufacturer does not know the characteristics of your water supply. The quality of water supplies may vary seasonably or over a  

period of time. Your water usage may vary as well. Water characteristics can also change if the drinking water appliance is moved to a new 

location. The Manufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements, and 

we do not authorize others to assume such obligation on our behalf. 

This Limited Warranty does not cover any Manufacturer-supplied items that are defective as a result of the use of improper parts, equip-

ment or materials. This warranty does not cover alterations or modifications of the unit, or failure of a unit caused by such alterations and 

modifications 

This Limited Warranty does not cover malfunctions of the unit due to tampering, misuse, alteration, lack of regular maintenance, misap-

plication, fouling due to hydrogen sulfide, manganese or iron, scaling from excessive hardness, turbidity greater than 1.0 NTU, Silt Density 

Index (SDI) greater than 5.0 SDI, or excessive membrane hydrolysis due to chlorine levels in excess of 1.0 mg/L (ppm).  In addition, damage 

to the unit due to fire, accident, negligence, act of God, or events beyond the control of the Manufacturer are not covered by this war-

ranty. 

Incidental and Consequential Damages Limitation

: The Manufacturer will not be responsible for any incidental or consequential damages 

as a result of the failure of this unit to comply with express or implied warranties or any defect in the unit, including but not limited to, lost 

time, inconvenience, damage to personal property, loss of revenue, commercial losses, postage, travel, telephone expenditures, or other 

losses of this nature. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this exclusion may 

not apply to you.

Owner’s Warranty Responsibilities

: As a condition of this Limited Warranty, the owner must ensure periodic maintenance of the system 

is performed as described in the literature enclosed with the system. Neglect, improper maintenance, abuse, modification or alteration of 

the unit will invalidate this Warranty.  Should your unit develop a defect or otherwise fail to perform in accordance with this warranty, you 

should contact the retailer from whom the product was originally purchased.

Implied Warranties

: The implied at-law warranties of merchantability and fitness for a particular purpose shall terminate on the date one 

year after the date of purchase. Note: some states do not allow limitations on how long an implied warranty lasts, so the above limitations 

may not apply to you.

Other Rights: 

This Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Содержание Cascade

Страница 1: ...ida Alavardo Temecula CA 92590 800 451 9343 www nimbuswater com DRINKING WATER FILTRATION SYSTEM 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com Owner s Manual Installation Guide ascade C ...

Страница 2: ...2590 800 451 9343 www nimbuswater com Please fill out this form immediately after installation and retain for future reference Model Number NS 14 __ __ Code __ __ __ __ __ On right side of frame below model number Install Date Service Phone ...

Страница 3: ...roper use of common hand and power tools If you are not familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the installation of this system consult a licensed professional such as a contractor or plumber NOTE This system has been designed for installation by licensed professionals such as a contractor or plumber System Performance System C...

Страница 4: ...sumes no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied items that are defective as a result of the use of improper parts equip ment or materials This warranty does not cover alterations or modifications of the unit or fa...

Страница 5: ...ity with standard sink plumbing and proper use of common hand and power tools Improperly installed systems could result in water damage due to leaks or flooding The connection parts kit supplied with the Cascade Drinking Water Filtration System includes components which repre sent the most common under sink plumbing connections currently in use within the United States If these components do not m...

Страница 6: ... connect feed connector install the feed adapter into the angle stop Firmly press the green 1 4 tubing into the 1 4 connector OR Using the green 1 4 tubing install the compression nut plastic ferrule and plastic tube insert Secure the tubing into the feed connector Tighten the tubing retaining nut securely 5 Connect the cold water faucet feed line to the feed adapter 7 Attach the small Feed Valve ...

Страница 7: ... faucet 3 Loosely thread the 3 8 washer 2 serrated washer 3 and mounting lock nut 4 onto the threaded stem 5 Thread faucet quick connect adapter 5 onto threads of faucet stem NOTE This connection should be hand tightened only Push end of 3 8 blue tubing located on the system up through the hole in the sink Press into open end of adapter 6 Push the faucet base assembly down through the sink hole 7 ...

Страница 8: ...ted location If desired the 6 self tapping screws may be used to secure the manifold unit in position by means of the top rear and bottom lip mounting holes 2 Route the blue tubing from the faucet assembly to the blue coded connector marked Feed on the top of the manifold unit 3 Take the green tubing already connected to the water feed valve and insert it into the green coded connec tor Push the t...

Страница 9: ...ed water valve to the system Observe all tubing and connections for several minutes to detect any leaks Allow the faucet to run for at least 3 minutes then close the faucet A small amount of carbon fines may be seen in the initial flushing of the system 4 Check fittings again for leaks after closing the faucet Checklist 1 Cascade unit is located where it will not be subject to physical impacts or ...

Страница 10: ...o side as necessary until the cartridge tubes are properly engaged in the manifold connectors Install the retaining clip ensuring the slide locks snap into place in the slots If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors Press top or bottom of cartridge to engage connectors until it snaps into place properly 6 Close t...

Страница 11: ...11 42445 Avenida Alavardo Temecula CA 92590 800 451 9343 www nimbuswater com ...

Отзывы: