Scrub System, Cylindrical
68
Service Manual – SCRUBTEC R466 ... FOCUS II Micro Rider
Brush Motor Disassembly/Assembly
Disassembly
1
Remove the cylindrical brush deck (see the procedure in “Cylindrical Brush Deck Disassembly/
Assembly” paragraph)
2
On the machine side where the brush motor has to be removed, unscrew the knobs and remove the side
skirt assembly
3 Remove the screws (A) and remove the case (B)
A
B
P100723