Solution System
114
Service Manual – SCRUBTEC R466 ... FOCUS II Micro Rider
Removal and Installation
Solution System Solenoid Valve/Filter Disassembly/Assembly
Disassembly
1 Place the machine on a hoisting system (if
available), then lift it. Otherwise, drive the
machine on a level floor.
2 Lower the brush deck
3 Lower and remove the squeegee from the holder
4 Turn the ignition key to “0” and disconnect the
batteries
5
On the right side of the machine, remove the
screws and nuts (A)
6 Disconnect the connector (B)
7 Disconnect the hose (C) and (D)
8
Recover the whole assembly and, at the
workbench, remove the solenoid valve (E), or the
filter assembly (F) by disconnecting/unscrewing
the connecting/fastening components.
Assembly
9 Assemble the components in the reverse order of
disassembly, and note the following:
◦ Before screwing the threaded fittings (G)
clean them, then apply Teflon tape, according
to the screwing direction
◦ When assembling the filter (F) the stamped
arrow (H) must be tuned in the direction of
the solution flow.
A
A
B
D
E
F
G
G
C
H
P100750