F
Overview of the placement of suction valve
parts.
Pic. F.17: Suction valves
Overview of the placement of pressure
valve parts
Pic. F20: Pressure valves
Valves
Assemble header ring in right position. Knob on
header ring must be placed in groove in
cylinderhead. Drop —do not knock it into the
right position.
Pic. F.18: Header ring
If the header ring is mounted wrongly and not
according to instruction, there is a big risk of
damaging the header ring and parts of it will
block pistons and valves in the pump or get
stucked in the non return valve in the unloader.