37
POSEIDON 5 NEW-NA5_en_Ver.1.0_20/12
Function
D
A1
Control
PCB
B3
Motor
thermal
switch.
B4
Reed
contact.
K1
Contactor.
M1
Motor.
S1
Main switch ON/OFF.
Operation of Poseidon 5 FA:
The PCB has following functions:
1. To start the motor when starting the machine.
2. To stop the motor when operation of the machine is finished.
3. To run the motor in by-pass for 20 sec. after flow stop was reached and B4 opened.
4. To record and store data concerning the machines work stiuations, operation and by-pass.
The PCB is protected ——————- by a fuse (6.3A—slow) placed on the board.
Pre-conditions:
Machine hooked up to adequate water and powerr supply.
Main switch S1 in position ”0” (OFF):
- There is mains voltage at the contacts of S1 and K1, but no power at the PCB
- Machine is still off.
Pic. D2: Wiring diagram.
Operation electrical system
Содержание Poseidon 5 Series
Страница 1: ...POSEIDON 5 NA5 SERVICE MANUAL ENGLISH ...
Страница 59: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 59 H 106420550 ...
Страница 60: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 60 H 106420552 ...
Страница 61: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 61 H 106420554 ...
Страница 62: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 62 H 106420558 ...
Страница 63: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 63 H 106420559 ...
Страница 64: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 64 H 106420564 ...
Страница 65: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 65 H 106420566 ...
Страница 67: ...67 POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 Notes ...
Страница 68: ...Nilfisk ALTO Division of Nilfisk Advance A S Industrivej 1 9650 Hadsund Denmark ...