Troubleshooting
POSEIDON 5 NEW-NA5_en_Ver.1.0_20/12
45
E
Unloader failures.
Symptom:
Machine does not stop when releasing the spray gun.
Cause:
Defective spring (1), or defective activation arm (3), or defective micro switch housing (4),
or defective micro switch (5).
Remedy:
Replace defective parts.
Symptom:
Machine does not stop when releasing the spray gun. Pump runs in by-pass mode with
very high pressure — approx 180bar.
Cause:
Non return valve piston (12) - O-ring (11) - Seat (13) defective
→
System leaks internally or
piston (12) closes too slowly caused by dirt/chalk.
Remedy:
Replace Non return valve kit or clean dirty parts.
Symptom:
Machine starts by itself and stops right away.
Cause:
Pressure system leaks between spray gun and pump
→
Cut-off pressure drops and the
activation arm (3) releases the micro switch (5), or leaks at gaskets 6, 8, 10, 11.
Remedy:
Check gaskets in spray gun - Check gaskets 6, 8, 10, 11 and replace if necessary.
Symptom:
Working
pressure too low.
Cause:
Machine by-passes water.
Remedy:
Spring (1) tension too low or leakage between ball (16) and seat.
1
2
3
4
5
6
7
8
9
10
16
11
12
15
14
13
Pic. E1: Unloader.
Содержание Poseidon 5 Series
Страница 1: ...POSEIDON 5 NA5 SERVICE MANUAL ENGLISH ...
Страница 59: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 59 H 106420550 ...
Страница 60: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 60 H 106420552 ...
Страница 61: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 61 H 106420554 ...
Страница 62: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 62 H 106420558 ...
Страница 63: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 63 H 106420559 ...
Страница 64: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 64 H 106420564 ...
Страница 65: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 65 H 106420566 ...
Страница 67: ...67 POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 Notes ...
Страница 68: ...Nilfisk ALTO Division of Nilfisk Advance A S Industrivej 1 9650 Hadsund Denmark ...