E
Troubleshooting
SM_POSEIDON 4_en_Ver.1.0_08.2012
16
Fig. E.1:
Troubleshooting 1
Fault
Cause
Remedy
Pressure drop
- Air in the system.
- High pressure nozzle
blocked / worn.
- Pressure control on the
spray lance is not set
correctly.
- Detergent container empty.
- Water inlet temperature
too high.
Vent the system by
operating the spray gun
several times at short
intervals .If necessarly
operate the cleaner for a
short time without the
High pressure hose
connected.
Clean / replace the high
pressure nozzle.
Set the required working
pressure.
Change container or close
detergent valve.
See technical data part ”B”.
Pressure
fluctuations
- Lack of water
- Water inlet hose is too long
or its cross-section too
small.
- Lack of water caused by
blocked water filter.
- Lack of water because
max. permissible suction
height has not been
heeded.
- Pump sucks in air
(suction mode)
Open water tap.
Use specified water inlet
hose(Refer to user manual).
Clean the water filter in the
water connection.
(Never work without water
filter).
See technical data part ”B”
Check that the suction set
is air tight.
The motor does not start when
the cleaner is switced on.
- The plug is not inserted
properly, i.e. there is no
current.
- The main fuse is switced off.
Check the plug, lead and
switch.
If necessary have them
replaced by a trained
electrician.
Switch on the main fuse.
Содержание POSEIDON 4 Series
Страница 1: ...Service Manual POSEIDON 4...
Страница 32: ...H Wiring diagrams SM_POSEIDON 4_en_Ver 1 0_08 2012 32...
Страница 33: ...H Wiring diagrams SM_POSEIDON 4_en_Ver 1 0_08 2012 33...
Страница 34: ...H Wiring diagrams SM_POSEIDON 4_en_Ver 1 0_08 2012 34...
Страница 36: ...36 SM_POSEIDON 4_en_Ver 1 0_08 2012 Notes...
Страница 37: ...Nilfisk ALTO Division of Nilfisk Advance A S Industrivej 1 9650 Hadsund Denmark www nilfisk alto com...