Function
Functional-block diagram
HP-Pump
Strainer
PV
Injektor Spray device
Water
Power
S1
Motor (M1)
B4
B3
Detergent
Dt.Valve
Fig. D.1:
Functional diagram POSEIDON 4 (1~)
Functional-block diagram 1~
Explanation for functional diagram
(Refer to technical data part B and wiring diagrams part H)
Preconditions:
-The high pressure cleaner is connected to adequate water and power supply.
Main switch S1 in ”OFF” position.
-There is main voltage to S1.
-Cleaner is still off.
Main switch S1 in ”ON” position.
-Gun closed : The cleaner starts up (if B4 is closed and B3 is closed) until cut-off pressure is
reached => end switch B4 opens => the cleaner stops.
-NOTE ! Static high pressure water between valve block - hose - gun .
-Gun activated: The pressure drops in pressure valve => the end switch B4 is activated =>
the cleaner starts up and runs at working pressure.
-Gun being closed: Working pressure increases to cut-off pressure => end switch opens =>
the cleaner stops.
-Detergent valve: The cleaner running at working pressure and the detergent valve open,
detergent is added by means of the vacuum in the injector to the high pressure water.
Содержание POSEIDON 4 Series
Страница 1: ...Service Manual POSEIDON 4...
Страница 32: ...H Wiring diagrams SM_POSEIDON 4_en_Ver 1 0_08 2012 32...
Страница 33: ...H Wiring diagrams SM_POSEIDON 4_en_Ver 1 0_08 2012 33...
Страница 34: ...H Wiring diagrams SM_POSEIDON 4_en_Ver 1 0_08 2012 34...
Страница 36: ...36 SM_POSEIDON 4_en_Ver 1 0_08 2012 Notes...
Страница 37: ...Nilfisk ALTO Division of Nilfisk Advance A S Industrivej 1 9650 Hadsund Denmark www nilfisk alto com...