19
1)
Options / model variants
Original instructions
NEPTUNE 3
8.2 Other
Faults
Fault
Cause
Remedy
not ON
> Plug not connected to the
electrical plug socket
•
Put the plug into the electrical
socket.
•
Check fuse (see chapter 9.3 Techni-
cal Data)
Pressure too low
>
High pressure nozzle worn out •
Replace nozzle
>
Pressure regulation set to low
pressure or VarioPress-lance
1)
set to low water volume.
•
Turn the twist grip on safety control
block clockwise (+) or set Vario-
Press-lance
1)
to higher water volume
(see chapter 4.4)
Machine is running with
pulsating pressure and
makes knocking noise
>
Pump has drawn in air as the
detergent tank is empty
•
Close detergent valve. Remove
lance from gun. Operate spray gun
and let machine run until air in pump
is gone and the machine is running
normally/calm again.
No detergents drawn in
>
Detergent tank empty
•
Top up detergent tank
>
Dirt in detergent tank
•
Clean detergent tank
>
Suction valve at cleaning
agent inlet soiled
•
Remove suction valve and clean or
replace
Burner soots
>
fuel contamination
Contact Alto Service
>
Burner sooted or adjustment
incorrect
Indication light
Cause
Remedy
Green LED
and red
LED
fl ash alternately
>
Motor overheated
•
Turn main switch in position
„OFF“, let machine cool down
•
Remove/disconnect extension
cable
•
Possible phase failure; have elec-
trical connection checked
>
Machine overheated
Contact Alto Service
Green LED
fl ashes
slowly
red LED
fl ashes
rapidly
>
>
Flame sensor sooted
Ignition or fuel system failure
•
Clean fl ame sensor (see chapter
7.2.5).
Contact Alto Service
Cold water operation possible
Содержание NEPTUNE 3
Страница 1: ...301001540 C Operating instructions NEPTUNE 3 ...
Страница 2: ......