Nilfisk-ALTO CIP10/14 Скачать руководство пользователя страница 25

Vers. 2.1

 - 22.04.08

 

 

 

 

 

 

 

                

19

 

 

 

 

 

Pos. No. 

 

Article No. 

 

Description 

 

Number 

34 357300 

Union, 

half 

35 

638500 

Quick fitting for air, 1/4”x8 mm 

36 

635650 

Air filter, pressure regulator and gauge  

37 

634000 

Closing valve for air, 1/4” 

38 

641005 

Threaded nipple, 1/4” 

39 642200 

Socket 

1/4” 

40 

647300 

Angle with union 

41 

921510 

Form socket, 1/4”x1/8” 

42 

647804 

Dosing valve for detergent 

43 648050 

Non-return 

valve 

44 924500 

Tee 

1/4” 

45 

647704 

Form socket, 1/4”x1/8” 

46 659100 

Screwed 

connection 

47 

359906 

Hose, rinsing, 500 mm 

48 3599030500 

Bottom 

outlet 

49 

3599030502 

Bottom outlet, left 

50 

3599030504 

Bottom outlet, right 

51 359905 

Manifold, 

outlet 

52 

639921 

Injector, CIP 10/14 

53 - 

Air 

manifold 

54 

530200CIP 

Solenoid valve 24 VDC 

17 (21) 

54 

534000 

Solenoid valve 24 VAC 

17 (21) 

54 

534100CIP 

Solenoid valve 110 VAC 

17 (21) 

54 

530100CIP 

Solenoid valve 220 V/50Hz 

17 (21) 

54 

534400 

Solenoid valve 115 VAC 

17 (21) 

55 

359703 

Outlet, CIP 14 

56 

359701 

12-pipe outlet  

57 

659000

 

Pressure gauge for water

 

1

 

58 

638601 

Quick fitting for air 8x1/4”x8 

59 

647702 

1/8”x12.5 mm hose nipple for detergent 

60 640300 

Air 

nozzle 

61 

639100 

Seal kit for air nozzle 

62 0605532 

Ball 

valve 

63 

640500 

O-ring for chemical nozzle 

64 

640401 

Chemical nozzle, ø 2.0 

65 

640404 

Chemical nozzle, ø 3.5 

66 

632800 

Ball valve 1/2” 

67 382400 

Nipple, 

1/2”x1/4” 

 

Содержание CIP10/14

Страница 1: ...UK Vers 2 0 07 02 07 Directions for Use Alto Danmark A S Automatic Pump Station CIP10 14...

Страница 2: ......

Страница 3: ...Vers 2 1 22 04 08...

Страница 4: ......

Страница 5: ...3 2 4 Layout Drawing 3 3 Start Up Procedures 5 4 System Safety 7 5 Maintenance 8 6 Trouble Shooting and Remedy 9 7 Flow Diagram 13 8 Identification Plate 14 9 Technical Data 15 10 Warranty 16 11 Mate...

Страница 6: ...Vers 2 1 22 04 08...

Страница 7: ...t your operational staff reads these directions for use prior to installation and start of operation Operation as laid down in the directions for use will ensure an optimum level of hygiene and a mini...

Страница 8: ...at a water pressure of 3 5 bar At a water pressure lower than 3 5 bar the water pipe must be minimum 1 1 2 38 mm d The equipment is fitted with a filter on the supply pipe e The pressure loss in the s...

Страница 9: ...sed air connection for pump station CIP10 14 15 on page 4 2 3 Supply of Detergents a Place the can with the suitable detergent in can holder b Check the detergent hose filter for impurities c Put the...

Страница 10: ...12 Switch for selection of foam rinse 4 Pump manual 5 Non return valve 13 Filter regulator pressure gauge 6 Chemical adjust foam automatic 14 Filter regulator pressure gauge 7 Chemical adjust disinfe...

Страница 11: ...The foam quality is perfect when the foam is moist and small bubbles are created If the consistency is too thin the foam will slide off quickly As a result the time of action will be insufficient and...

Страница 12: ...foam position 12 on page 4 and open the spray gun outlet valve After approx 5 seconds the pump starts automatically by means of the built in flow switch f The foam quality is perfect when the foam is...

Страница 13: ...itch If all valves are closed and there is no flow in the flow switch the flow switch disconnects the pump after the pre programmed time interval On the outlet pipe a non return valve is fitted to pre...

Страница 14: ...d experience have sufficient knowledge of low pressure cleaners or similar equipment and who are familiar with the state work security regulations accident preventing regulations lines and generally a...

Страница 15: ...of rotation of pump z Connect the pump correctly Flow switch defective z Call for skilled persons Pressure gauge defective z Replace pressure gauge Insufficient water supply z z Ensure water supply Fi...

Страница 16: ...tion of pump not correct Check the program call for assistance by FRIGOSCANDIA if necessary Open inlet valve of machine Change direction of rotation of pump in accordance with arrow on pump Unstable o...

Страница 17: ...unction correctly The non return valve in the injector is blocked up The dosing valve for detergent is blocked up The filter for detergent is blocked up The suction hose is not put into the detergent...

Страница 18: ...or f manual rinse 10 Injector foam 32 Ball valve w actuator f manual foam 11 Dosing valve foam 33 Injector f foam 12 Non return valve foam 34 Dosing valve foam 13 Filter foam 35 Non return valve foam...

Страница 19: ...Vers 2 1 22 04 08 13 8 Identification Plate 1 Producer 2 Serial number 3 Type 4 Date 5 Order number 6 Maximum pressure 7 Voltage 8 Frequency 9 Water volume 10 Consumption of air 11 Maximum temperature...

Страница 20: ...ion H x W x D CIP 10 Total dimension H x W x D CIP 14 Max air inlet pressure Min air supply Air quality in accordance with ISO 8573 1 Min inlet flow for start of plant 25 bar 12 bar inlet pressure 25...

Страница 21: ...hoses rubber parts or synthetic materials natural wear and tear as well as damage caused by careless and inappropriate treatment including transport damage are not covered by the guarantee Further the...

Страница 22: ...Vers 2 1 22 04 08 16 11 Material and Spare Parts List CIP 10...

Страница 23: ...Vers 2 1 22 04 08 17 CIP 14...

Страница 24: ...334603 Pump coupling inlet 1 17 850400 Pump CRN 4 120 50Hz until 27 06 05 1 17 0604044 Pump CRN 4 80 60Hz until 27 06 05 1 17 0604070 From 28 06 05 Pump CRI 5 16 50Hz 1 17 0604076 From 28 06 05 Pump...

Страница 25: ...ottom outlet left 1 50 3599030504 Bottom outlet right 1 51 359905 Manifold outlet 1 52 639921 Injector CIP 10 14 1 53 Air manifold 1 54 530200CIP Solenoid valve 24 VDC 17 21 54 534000 Solenoid valve 2...

Страница 26: ...1 74 641700 Coupling part male 1 2 1 75 379601 FH low pressure spraygun 1 76 676800 Tornado nozzle 25 30 1 77 353700 Flushing pipe 750 mm w Tornado nozzle 25 30 1 78 643001 Foam nozzle 50 200 1 79 11...

Отзывы: