3. Start-Up 

Procedures 

 
 
Automatic Cleaning 

 
a) 

Set a scale value of approx. "4" on the dosing valve for detergents (6 
and 7 on page 4). The value set is in no way related to the percentage of 
detergent sucked up during operation. Dependent on the type of 
detergent, final adjustment of the valve must be made during operation. 

 
b) 

Start the automatic plant from the control unit by means of the entered 
program. 

 
c) 

Adjust the air pressure at 5 bar on the reducing valve for air (13 on page 
4). Check the air pressure on the pressure gauge for air (13 on page 4). 

 
 

NOTE!

 

 

When adjusting the reducing valve for air, carefully pull up the knob and 
turn it right for pressure increase and left for pressure decrease. 

 
d) 

The foam quality is perfect when the foam is moist and small bubbles 
are created. If the consistency is too thin, the foam will slide off quickly. 
As a result, the time of action will be insufficient and detergents will not 
be utilised optimally. 

 
e) 

Insufficient foam quality is caused by 

 
 

- too low concentration of detergent 

 

- too high temperature of inlet water 

 

- insufficient air quantity and/or pressure 

 

- unsuitable detergent 

 

Manual Cleaning

 

 
 

CAUTION!

 

a) 

Ensure that the spray gun/outlet valve is closed. 

 
b) 

Set a scale value of approx. “4” on the dosing valve for detergents (8 on 

page 4). The value set is in no way related to the percentage of detergent 
sucked up during operation. Dependent on the type of detergent, final 
adjustment of the valve must be  made during operation. 
 
c) 

Adjust the air pressure to 5 bar on the reducing valve for air (14 on page 

4). Check  

the air pressure on the pressure gauge for air (14 on page 4). 

 
 
 

NOTE!

 

Содержание CIP10/14

Страница 1: ...UK Vers 2 0 07 02 07 Directions for Use Alto Danmark A S Automatic Pump Station CIP10 14...

Страница 2: ......

Страница 3: ...Vers 2 1 22 04 08...

Страница 4: ......

Страница 5: ...3 2 4 Layout Drawing 3 3 Start Up Procedures 5 4 System Safety 7 5 Maintenance 8 6 Trouble Shooting and Remedy 9 7 Flow Diagram 13 8 Identification Plate 14 9 Technical Data 15 10 Warranty 16 11 Mate...

Страница 6: ...Vers 2 1 22 04 08...

Страница 7: ...t your operational staff reads these directions for use prior to installation and start of operation Operation as laid down in the directions for use will ensure an optimum level of hygiene and a mini...

Страница 8: ...at a water pressure of 3 5 bar At a water pressure lower than 3 5 bar the water pipe must be minimum 1 1 2 38 mm d The equipment is fitted with a filter on the supply pipe e The pressure loss in the s...

Страница 9: ...sed air connection for pump station CIP10 14 15 on page 4 2 3 Supply of Detergents a Place the can with the suitable detergent in can holder b Check the detergent hose filter for impurities c Put the...

Страница 10: ...12 Switch for selection of foam rinse 4 Pump manual 5 Non return valve 13 Filter regulator pressure gauge 6 Chemical adjust foam automatic 14 Filter regulator pressure gauge 7 Chemical adjust disinfe...

Страница 11: ...The foam quality is perfect when the foam is moist and small bubbles are created If the consistency is too thin the foam will slide off quickly As a result the time of action will be insufficient and...

Страница 12: ...foam position 12 on page 4 and open the spray gun outlet valve After approx 5 seconds the pump starts automatically by means of the built in flow switch f The foam quality is perfect when the foam is...

Страница 13: ...itch If all valves are closed and there is no flow in the flow switch the flow switch disconnects the pump after the pre programmed time interval On the outlet pipe a non return valve is fitted to pre...

Страница 14: ...d experience have sufficient knowledge of low pressure cleaners or similar equipment and who are familiar with the state work security regulations accident preventing regulations lines and generally a...

Страница 15: ...of rotation of pump z Connect the pump correctly Flow switch defective z Call for skilled persons Pressure gauge defective z Replace pressure gauge Insufficient water supply z z Ensure water supply Fi...

Страница 16: ...tion of pump not correct Check the program call for assistance by FRIGOSCANDIA if necessary Open inlet valve of machine Change direction of rotation of pump in accordance with arrow on pump Unstable o...

Страница 17: ...unction correctly The non return valve in the injector is blocked up The dosing valve for detergent is blocked up The filter for detergent is blocked up The suction hose is not put into the detergent...

Страница 18: ...or f manual rinse 10 Injector foam 32 Ball valve w actuator f manual foam 11 Dosing valve foam 33 Injector f foam 12 Non return valve foam 34 Dosing valve foam 13 Filter foam 35 Non return valve foam...

Страница 19: ...Vers 2 1 22 04 08 13 8 Identification Plate 1 Producer 2 Serial number 3 Type 4 Date 5 Order number 6 Maximum pressure 7 Voltage 8 Frequency 9 Water volume 10 Consumption of air 11 Maximum temperature...

Страница 20: ...ion H x W x D CIP 10 Total dimension H x W x D CIP 14 Max air inlet pressure Min air supply Air quality in accordance with ISO 8573 1 Min inlet flow for start of plant 25 bar 12 bar inlet pressure 25...

Страница 21: ...hoses rubber parts or synthetic materials natural wear and tear as well as damage caused by careless and inappropriate treatment including transport damage are not covered by the guarantee Further the...

Страница 22: ...Vers 2 1 22 04 08 16 11 Material and Spare Parts List CIP 10...

Страница 23: ...Vers 2 1 22 04 08 17 CIP 14...

Страница 24: ...334603 Pump coupling inlet 1 17 850400 Pump CRN 4 120 50Hz until 27 06 05 1 17 0604044 Pump CRN 4 80 60Hz until 27 06 05 1 17 0604070 From 28 06 05 Pump CRI 5 16 50Hz 1 17 0604076 From 28 06 05 Pump...

Страница 25: ...ottom outlet left 1 50 3599030504 Bottom outlet right 1 51 359905 Manifold outlet 1 52 639921 Injector CIP 10 14 1 53 Air manifold 1 54 530200CIP Solenoid valve 24 VDC 17 21 54 534000 Solenoid valve 2...

Страница 26: ...1 74 641700 Coupling part male 1 2 1 75 379601 FH low pressure spraygun 1 76 676800 Tornado nozzle 25 30 1 77 353700 Flushing pipe 750 mm w Tornado nozzle 25 30 1 78 643001 Foam nozzle 50 200 1 79 11...

Отзывы: