Nilfi sk-Advance A/S
Sognevej 25
DK-2605 Brøndby
Denmark
Tel.: +45 43 23 40 50
Fax: +45 43 43 77 00
mail.com@nilfi sk-advance.com
www.nilfi sk.com
ATTENTION!
Do not use the machine before you have read and understood the User Manual.
The machine
doesn’t work
as it should.
The machine does
not collect debris/
dust
TROUBLESHOOTING
SW900
1. Check if the battery is charged and
that the charger cable is disconnect-
ed from the main.
1. Check if the fl aps are correctly ad-
justed and not worn out.
2. Check if the main battery connector
is properly connected.
3. Check if the main circuit breaker is
open.
4. ecure that the upper cover and hop-
per is in the right position.
2. Check if the panel fi lter is clean the
gasket properly sealing.
3. Check if the gasket is damaged.
The machine do
not sweep.
1. Adjust the main broom position by
the knob.
2 Adjust the side brooms position by
the register screw.
3. Check if there are external materials
avoiding brush rotating.
4. Check if the circuit breaker for side
brooms is open.
4. Check if the hopper is full.
5. Replace the brooms if the bristles are
wornout.