USER MANUAL
ENGLISH
1465371000 - SW900
19
HOPPER POSITION MICROSWITCH OPERATION CHECK
While the engine is running, remove the hopper (14) and check that the engine stops immediately.
If the engine keeps running when the hopper (14) is removed, contact an authorised Service Center or Retailer immediately.
FUSE CHECK/REPLACEMENT/RESET
1.
Drive the machine on a level floor. Make sure that the machine cannot move independently.
2. Turn the ignition key (2) to “0”.
Fuse Check
3. Check one of the following fuses for deactivation:
(31): Right side broom motor fuse FB (5 A)
(32): Left side broom motor fuse FC (5 A) (optional)
Reset any deactivated fuse, when the component that caused deactivation has fully cooled down.
Fuse check/replacement
4. Disengage the front latch (22) and open the engine and dynamotor hood (21).
5. Check/replace the relevant fuse among the following:
(29): Main fuse FA (20 A).
(30): Electrical filter shaker fuse F1 (5 A).
Reassembly
6. Close the engine and dynamotor hood (21) and engage the front latch (22).