29
SH AUTO
Original Instructions
7 Technical
Data
Model
SH AUTO
SH AUTO
SH AUTO
5M-100/500 D
5M-100/500 DSS
5M-100/500 E
NA5.2
NA5.2
NA5.2
NP2 coil
NP2 Coil
Voltage
V
400
400
400
Number of phases
3
3
3
Frequenzy Hz
50
50
50
Total current cons.
A
10.8
10.8
27
Power consumption
kW
6.4
6.4
16.8
Water connection:
Max. pressure, inlet water
bar
10 / (6*)
10 / (6*)
10 / (6*)
Min. pressure, inlet water
bar
1.0
1.0
1.0
Max. temperature, inlet water
°C
30
30
30
Pump pressure
bar
100
100
100
Flow Qiec
l/h
500
500
500
Flow reduction
l/h
300
300
300
Heating tank, volume
liter
31
31
31
Spray lance:
Nozzle type
.0370
.0370
.0370
Dimensions (H x W x D)
mm
1635x1090x725
1635x1090x725 1550x1090x725
1670x1025x715
Weight kg
204
204
182
Pump oil type
Castrol Alphasyn T 150 Castrol Alphasyn T 150 Castrol Alphasyn T 150
Pump oil amount
l
0.7
0.7
0.7
*) Applying to machines with the optional water softening equipment.
We reserve the right to make alterations.
Diesel according to EN 590 (up to 7% bio diesel) can be used with the following restrictions:
Maximum storage time in high pressure cleaner diesel tank: 1 month.
Diesel stored externally for more than 6 months is not allowed to be filled into Nilfisk high pressure
cleaners.
Diesel EN 590 is not recommended for use in HPW's at an ambient temperature below 0°C.
Diesel EN 590 from an open container must not be used.