SD 400 / SD 430 / SD 500 / SDP 430
2 _5 Maintenance / care
18
2 _5
Maintenance / care
2
_5.1 Precautionary measures prior to
cleaning and maintaining the machine
Prior to maintenance and cleaning
operations, the machine must be
disconnected from the mains by
disconnecting the mains plug. Accidents
due to electrical voltage and moving parts
may be avoided in this manner.
When maintaining or servicing the
machine, when exchanging parts or
resetting to a different function it must be
ensured that the machine cannot start
accidentally. It must also be protected
from rolling off or tilting and no parts may
be in a position that may cause them to
fall down or close by themselves.
If in doubt about any safety matters
consult the manufacturer or their
authorised agency before putting the
machine into use.
2 _5.2
Trouble shooting and fault eradication
Table 3
If the fault in the machine is not eradicated
after following the procedure according to
the above table, the manufacturer’s
customer service must be informed and
commissioned with the execution of the
necessary repair work.
2 _5.3
Cleaning the machine
Keep the bottom part of the machine in clean condition.
Clean or exchange brushes and floor pads.
2 _5.4
Pad care
After using, clean coarse soiling from the pads, which
can be used on both sides, and replace the pads within
good time in order to achieve good cleaning results.
2 _5.5
Daily examination
•
Check mains cable for damage.
2 _5.6
Annual maintenance
An electrically-driven machine must be checked
annually according to VDE-702 or comparable
international regulations
This examination should be carried out by
a service technician who has been trained
by the manufacturer!
Fault
Cause
Remedy
Maschine does not function
•
the main plug (2, picture 1) is not
correctly inserted
•
the unit socket (5, Picture 1) is
not correctly inserted
•
ensure correct seating
•
ensure correct seating
SDP 430 only:
•
the thermo-protection has cut the
motor off.
•
leave machine to cool down for 5 - 10
minutes approx.
Machine runs in a jerky manner
•
soiled pad (1, picture 2)
•
Pad unevenly worn
•
Pad not fastened in centre of pad
holder
•
beat pad out / if necessary, wash out
under water
•
insert new pad
•
remove pad from pad holder, fasten in
centre of pad holder
Machine wobbles
•
Pad holder or brush not installed
correctly
•
remove pad holder or brush and re-install
Содержание SD 400