TROUBLESHOOTING
Fault
Causes
Remedies
The vacuum suddenly
stops
Clogged primary filter
Shake the filter. Replace
it if this is not sufficient
Motor protector tripper
Clogged suction pipe
Check the setting.
Check the suction pipe
and clean it.
Check the power draw of
the motor. Contact an
authorized after-sales
service centre if
necessary
Dust leaks from the
vacuum
The filter is torn
Change it for another of
identical category.
Inadequate filter
Change it for another of
suitable category and
check.
The vacuum blows
instead of sucking
Incorrect connections to
the mains socket
Check all earth
connections. Particularly
check the suction inlet
fitting.
Remove the plug and
invert two of the live
wires.
Electrostatic current on
the vacuum
Non existent or
inefficient earthing
Lastly, the pipe must
strictly antistatic