background image

1)

OEL=Occupational Exposure Limit, 

*) 

Optional accessories / Option depending on model

Original instruction

7

, i.e. the machine can be used as an extension 

cord.
In position             the machine can be switched on 
and off by the power tool connected. Dirt is picked 
up from the source of dust immediately. To comply 
with regulations, only approved dust producing tools 
should be connected.

The maximum power consumption of the connected 
electrical appliance is stated in section “Specifica-
tions”.

Before turning the switch to position           ensure 
that the tool connected to the appliance socket is 
switched off.

3.3 Push&Clean

*)

The “PC” machine is equipped with a semi automatic 
filter cleaning system, Push&Clean. The filter clean-
ing system must be actuated latest when the suction 
performance is no longer sufficient. Regular use of 
the filter cleaning feature maintains suction perfor-
mance and increases the lifetime of the filter. For 
instruction see quick reference guide.

3.4 InfiniClean

*)

The “IC” machine is equipped with an automatic filter 
cleaning system, InfiniClean. A frequent cleaning cy-
cle will automatically run during operation to ensure 
that suction performance is always at its best.

If suction performance decreases or in extensive 
dust applications a manually filter cleaning operation 
is recommended:
• 

Switch off the machine

• 

Close the nozzles or suction hose opening with 
the palm of your hand.

• 

Turn the switch to position „I“ and let the ma-
chine operate at full speed for approx. 10 sec-
onds with the suction hose opening closed.

If suction power is still reduced take out the filter and 
clean mechanically or replace filter.

For certain applications, like wet pick up, it is recom-
mended to turn off the automatic filter cleaning sys-
tem. For details see chapter 3.1.

3.5 

Flow rate warning

CAUTION

Check that all the filters are present and 
properly fitted.
The machine is equipped with a system to 
monitor air velocity and Dust Class H filter 
condition

*)

. Before picking up dust with oc-

cupational exposure limit values, check the 
volume flow monitor.
When the motor is running, hold the suction 
hose shut to reduce the volume flow. The LED 
indicator on front panel will light after approx. 
1 second. The acoustic warning sounds after 
some additional seconds.

Set the diameter setting to the actual hose size.
When LED indicator lights, air velocity is be-
low 20 m/s.
• 

check if container or filter bag is full.

• 

check if air flow is reduced in suction 
hose, tube/nozzle, filter.

When LED indicator lights, Dust Class H or 
HEPA filter is missing, damaged or clogged. 
The filter needs to be installed or replaced to 
obtain needed air flow.

3.6 Antistatic 

connection

*)

CAUTION

The machine is equipped with an antistatic 
system to discharge any static electricity that 
may develop during dust pick-up.

The antistatic system is placed in front part of the 
motor top and creates an earth ground connection 
to the inlet fitting of the container. For proper func-
tion the use of an electrical conductive or antistatic 
suction hose is recommended. When inserting the 
optional disposal bag make sure the antistatic con-
nection is kept.

3.7 

Cooling air filter

To protect the electronics and motor, the machine is 
equipped with a cooling air diffusor. Clean the cool-
ing air diffusor regularly. 
For areas with a high concentration of fine dust in 
the surrounding air it is recommended to equip the 
machine with an optional cooling air filter cartridge to 
prevent dust from settling inside the air channels and 
motor. Contact your local sales representative.

CAUTION

 If cooling air filter is clogged by dust the over-
load protection switch in the motor can be 
activated. In such case switch off the ma-
chine, clean cooling air filter and allow ma-
chine to cool for approx. 5 minutes.

3.8 Wet 

pick-up

CAUTION

The machine is equipped with a water level 
limit system which shuts off the machine when 
the maximum liquid level is reached.
When this occurs, switch off the machine. 
Disconnect the machine from the socket and 
empty the container. Never pick up liquids 
without the water level limit system and filter 
in place.  
Picking up liquids.
• 

Do not pick up flammable liquids

• 

Before liquids are picked up, always re-
move the filter bag/wastebag and check 
that the water level limit works properly.

• 

If foam appears, stop work immediately 
and emty the tank.

Содержание HS 42 L30 MC PC

Страница 1: ...che Stäube Entleerung und Wartung einschließlich Entfernung des Staubbeutels dürfen nur von sachkundigen Personen vorgenommen werden die geeignete persönliche Schutz ausrüstung tragen Nicht einschalten bevor das komplette Filtersystem installiert und die Funktion der Volumenstrom kontrolle überprüft worden ist ...

Страница 2: ...VHS 42 L30 MC PC VHS 42 L30 HC PC VHS 42 L40 MC PC VHS 42 L40 HC PC ...

Страница 3: ...Operating elements 3 1 2 4 5 6 7 8 9 10 13 12 14 11 ...

Страница 4: ...1A 2A M 1 2 1 1 2 1 3 3 4 4 5 5 5 6 6 ...

Страница 5: ...3A M 4A 1 1 2 4 3 5 6 6 1 2 1 4 3 6 5 6 ...

Страница 6: ...5A ø21 ø21 ø27 ø27 ø32 ø32 ø36 ø36 ø38 ø38 5A A 2M IC 2H IC 2M PC 2H PC MIN MAX MAX MIN MAX MIN B ø 2 1 ø 2 7 ø32 ø 3 6 ø 3 8 3 4 2 1 2M PC 2H PC 2M IC 2H IC ...

Страница 7: ...6A 6A 1 2 ...

Страница 8: ...7A x4 1 1 2 2 3A 3A 4A 4A 4A 4A 3B 4B 4B ...

Страница 9: ...8A x2 x2 x4 1B 20 m s 1 3 2 ...

Страница 10: ...2B 3x Push Clean 3B 10 sec InfiniClean 1 2 3 1 2 ...

Страница 11: ...4B 1C MAX MIN A B 1 2 2 3 4 2 3 4 2 5 5 6 7 ...

Страница 12: ...1D M 2D M 1 2 3 2 4 5 6 7 8 8 2 1 1 4 3 6 7 8 8 5 ...

Страница 13: ...3D 4D M 2 2 3 1 4 5 6 8 9 9 4 6 5 2 3 1 7 ...

Страница 14: ...4D 5D x4 8 7 1 1 2 4 3 5 ...

Страница 15: ...6D 7D 1 2 3 4 5 6 7 1 2 1 3 4 5 ...

Страница 16: ...7D 6 7 8 8 ...

Страница 17: ...ge C Connecting electrical appliances 1C Power tool adaption D Maintenance 1D Filter bag replacement 2D Disposal bag replacement 3D Safety filter bag replacement 4D Filter replacement Dust Class M H 5D Essential filter replacement Dust Class H 6D Motor cooling air diffuser cleaning 7D Gaskets and floater cleaning Contents 1 Safety instructions 2 1 1 Symbols used to mark instructions 2 1 2 Instruct...

Страница 18: ...e with the following instructions This machine is intended for commercial use for ex ample in hotels schools hospitals factories shops offices and rental businesses This machine is also suitable for industrial use such as e g plants construction sites and workshops Accidents due to misuse can only be prevented by those using the machine READ AND FOLLOW ALL SAFETY INSTRUC TIONS Any other use is con...

Страница 19: ... to 20 m 1 5 mm2 2 5 mm2 20 to 50 m 2 5 mm2 4 0 mm2 1 6 Guarantee Our general conditions of business are applicable with regard to the guarantee Unauthorised modifications to the appliance the use of incorrect brushes in addition to using the appli ance in a way other than for the intended purpose exempt the manufacturer from any liability for the resulting damage 1 7 Important warnings WARNING To...

Страница 20: ...to a service center or dealer If foam or liquid es capes from the machine switch off immediately The machine may not be used as a water pump The machine is intended for vacuuming air and water mixtures Connect the machine to a properly earthed mains supply The socket outlet and the extension cable must have an operative protective conductor Provide for good ven tilation at the working place Do not...

Страница 21: ... e g magnesium or aluminium dust etc WARNING Using the appliance for as bestos abatement work ac cording to German regulation TRGS 519 To pick up ma terials containing asbestos Dust Class H machines with type designation VHS 42 HC can be used for picking up asbestos Use a suction hose with a maximum diameter of 36 mm Use the closable plastic sack to ensure dust free transport of the appliance and ...

Страница 22: ... the tubes with the hose handle twist the tubes in order to ensure that they are properly fitted Attach suitable nozzle to the tube Choose nozzle depending on what type of material that is to be picked up If used for dust extraction in connection M with dust producing tool then connect end of suc tion hose with appropriate adapter Check that hose diameter setting corraspondes to actual hose dia me...

Страница 23: ...or is running hold the suction hose shut to reduce the volume flow The LED indicator on front panel will light after approx 1 second The acoustic warning sounds after some additional seconds Set the diameter setting to the actual hose size When LED indicator lights air velocity is be low 20 m s check if container or filter bag is full check if air flow is reduced in suction hose tube nozzle filter...

Страница 24: ...ng the carboard piece with the rubber membrane through the vacuum inlet Make sure that the rubber membrane is passing past the heightening at the vacuum inlet Safety filter bag check bag to ensure the fill factor Replace dust bag if necessary Wear mask and pro tective clothing when removing the old bag Carefully remove the dust bag connection from the inlet fitting Close the dust bag connection wi...

Страница 25: ... chine in such a manner that there is no danger for maintenance staff or other persons In the maintenance area Use filtered compulsory ventilation Wear protective clothing Clean the maintenance area so that no harmful substances get into the surroundings CAUTION In the case of asbestos abatement wear additional single use clothing Wear a P2 breathing mask Before removing the machine from the area ...

Страница 26: ...r appliance socket W 2400 2400 2400 2400 1100 1100 1100 Mains frequency Hz 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Fuse A 16 16 16 16 10 10 10 Protection grade moist dust IPX4 Protection class electrical I Max Airflow l s m 3 h CFM 75 270 159 Max Vacuum kPa hPa in H 2 0 25 250 100 Sound pressure level L PA IEC 60335 2 69 dB A 69 2 Working sound level dB A 60 2 Vibration ISO 5349 a h m s 2 2 5 We...

Страница 27: ...414021 www nilfisk it JAPAN Nilfisk Inc 1 6 6 Kita shinyokohama Kouhoku ku Yokohama 223 0059 Tel 81 45548 2571 www nilfisk com MALAYSIA Nilfisk Sdn Bhd Sd 33 Jalan KIP 10 Taman Perindustrian KIP Sri Damansara 52200 Kuala Lumpur Tel 60 3603 627 43 120 www nilfisk com MEXICO Nilfisk de Mexico S de R L de C V Pirineos 515 Int 60 70 Microparque Industrial WSantiago 76120 Queretaro Tel 52 442 427 77 00...

Отзывы: