FORM NO. 56043058 Hydro-Retriever™ 3800 / 2042 / BR 1100 -
17
SOLUTION SYSTEM
SOLUTION FLOW CONTROL VALVE REMOVAL
1
Drain the solution tank using the drain hose.
2
Open the right side scrub brush access door then remove the skirt assembly (2 knobs) to access the valve.
3
See Figure 5. Loosen the (2)
(I)
Hose Clamps and pry off the inlet & outlet solution hoses from the valve’s barbed fittings.
4
Remove the Retainer Ring
(J)
from the solution control rod and separate from the valve handle.
5
Remove the (2)
(K)
Hex Nuts securing the valve Mounting Bracket
(L)
and complete the removal of the valve and bracket.
SOLUTION FILTER HOUSING REMOVAL
1
Drain the solution tank or put the flow control lever in the full OFF position to prevent solution loss.
2
Open the right side scrub brush access door then remove the skirt assembly (2 knobs) to access the solution filter.
3
See Figure 5. Remove (spin off) the filter bowl for easier access to the inboard mounting clamps.
4
Loosen the (2) Hose Clamps
(M)
and pry off both hoses (inlet & outlet) from the filter housing fittings.
5
Remove the (2) Hose Clamps
(N)
that secure the filter housing to the frame mounting bracket and pull the solution filter housing out from
under the machine.
FIGURE 5
FRONT
I
Electrical
Solenoid Valve
J
K
L
N
M
Drain Hose
Solution Filter
Solution Flow
Control Valve
revised 10/01