FORM NO. 56041554 - Advenger
™
, Advenger
™
AXP / BR 600S series -
A-9
ENGLISH / A-9
INSTALL THE SQUEEGEE
1
Make sure the Squeegee
(19)
is up (O) and the Key Switch
(J)
is off (O). Hold the squeegee tool so that the curved ends point forward, then slide the
squeegee tool onto the Mount
(A)
(See Figure 2).
2
Hand tighten the Thumb Nuts
(B)
and then connect the vacuum hose to the Squeegee Tube
(C)
(vacuum hose should loop to the right).
FILL THE SOLUTION TANK
Read the cleaning chemical label and
fi
gure the proper amount of chemical to mix for a tank that holds 30 US gallons (113 liters).
Open the Solution Tank Cover
(2)
, then
fi
ll the tank 1/3 full of water, add the cleaning chemical, then
fi
ll the tank to 7.62cm (3 inches) from the top of the tank
opening (
fi
ll to bottom of the wall in tank opening).
NOTE:
AXP/EDS machines can either be used conventionally with detergent mixed in the tank or the
detergent dispensing system can be used. When using the AXP/EDS detergent dispensing do not mix detergent in the tank, plain water should be used.
CAUTION
!
Use only low-foaming, non-
fl
ammable liquid detergents intended for automatic scrubber machine applications. Water
temperature should not exceed 130 degrees Fahrenheit (54.4 degrees Celsius).
A
B
C
FRONT
FIGURE 2
revised 3/06