115
Service Manual – SC500
24 - Electrical System
Battery Charging
Note:
Charge the batteries when there is
only one flashing segment displayed
in the battery symbol, or at the end
of each shift. Keeping the batteries
charged make their life last longer.
CAUTION: When the batteries are
discharged, charge them as soon
as possible, as that condition
makes their life shorter. Check
for battery charge at least once a
week.
CAUTION: If the machine is not equipped
with on-board battery charger,
choose an external battery
charger suitable for the type of
batteries installed.
WARNING: When using lead (WET)
batteries, battery charging
produces highly explosive
hydrogen gas. Charge the
batteries in well-ventilated areas
and away from naked flames.
Do not smoke while charging
the batteries. Keep the recovery
tank raised until the battery
charging cycle is over.
WARNING: Pay close attention when
charging WET CELL batteries,
as there may be battery fluid
leakages. The battery fluid
is corrosive. If it comes in
contact with skin or eyes, rinse
thoroughly with water and
consult a physician.
1 (For WET CELL batteries only) Check the level
of electrolyte inside the batteries If necessary,
unscrew the caps and top up
2 When the correct level is restored, close the caps
and clean the tops of the batteries
Charging the Batteries with an External Battery
Charger
3 Check that the external battery charger is
suitable by referring to the relevant Manual
The battery charger voltage rating must be 24V
4 Disconnect the red battery connector with
handle and connect it to the external battery
charger
5 Connect the battery charger to the electrical
mains
6 After charging, disconnect the battery charger
from the electrical mains and from the battery
red connector
7 Connect the battery connector to the machine
8 Carefully lower the recovery tank
CAUTION: Never connect the battery
charger to the opposing part of
the red connector fixed to the
machine. The electronic system
could be irreparably damaged.
Battery charging with battery charger installed on
the machine
9 Plug the battery charger into the mains
electricity supply (the mains voltage and
frequency must be compatible with the battery
charger values shown on the machine serial
number plate)
Note:
When the battery charger is
connected to the electrical
mains, all machine functions are
automatically cut off.
10
When the first or second segment from the
left in the battery symbol is flashing, this
means that the battery charger is charging the
batteries
11 When the third segment from the left in the
battery symbol is flashing, this means that the
battery charger is finishing the battery charging
cycle
12 When all segments of the battery symbol
are steadily lit, the battery charging cycle is
complete
13 Disconnect the battery charger plug from the
mains and place it in its holder
14 Carefully lower the recovery tank
Note:
For further information about the
operation of the battery charger, see
the relevant Manual.