109
Service Manual – SC500
24 - Electrical System
Functional Description
The batteries (2 x 12V) are connected together in series by the cables
The battery charger (CH) is connected to the machine by two connectors (C) (power connection to the
batteries) and C3 (4-way signal connection)
The grey and white cables (1 and 2 of connector C3) are short circuited inside the battery charger CH when
this is not connected to the mains If this connection is not made, all machine functions are disabled
If the optional battery charger has not been installed, the relevant bridge must be used on connector C3
The “bridge” is installed at the Main machine controller J4 location as shown in a photo below
J4 bridge
connector
The green cable (terminal 4 of connector C3) is the data cable between the Main machine controller (EB1)
and battery charger (CH)
This connection allows the battery charger charging curve to the be set directly from the User interface
controller and to view the operational state of the battery charger during charging directly on the Display
controller
Battery Charger
When the battery charger (CH) is connected to the power supply, it provides a + 24V on J4 2: in this
condition the Main machine controller (EB1) disables all the control and functions except the battery status
indicator on the Display controller (EB3)