background image

I

N T E L L I G E N T

P

O W E R

C

O N T R O L L E R

13

by current. After the sequencing stops, the 

ON

LED should be

blinking. This means that the IPC-6 is ready to measure the
device’s “on” state. 

3.

Turn on the device. The front panel LED's will sequence to

the left and right while the Accusense

TM

circuitry measures

your device. After the sequencing of the LED's stops the 

OFF

LED will blink.

4.

Turn off the device. The front panel LED's will sequence to

the left and right while the Accusense

TM

circuitry checks your

device. After the sequencing of the LED's stops and the IPC-6
has confirmed the programming, all the front panel LED’s will
light while the IPC-6 stores the program into memory. You
are now back in normal operating mode.

To program the device plugged into the ”B” sensing outlet,
repeat steps 1 through 4 using the “B” button and outlet.
When you begin programming, the IPC-6 will display “Pb”
instead of “PA”.

Programming Switched 120 volt and 
Controlled (low voltage) Outlets

You will need to program 3 different parameters for each of
the switched outlets (1-6) and control outputs (C1, C2).

1.

Which trigger (A, B, or both) will activate the outlet?

Pressing both trigger buttons means that the outlet will be
active if either or both triggers are active.

2.

The turn on time delay (indicated by the 

ON

LED being lit). 

I

N T E L L I G E N T

P

O W E R

C

O N T R O L L E R

14

Program the delays for each outlet to build your "turn on"
sequence. Delays are calculated in 1 second increments after
your triggering device is turned "on" or "off". Therefore, if
you would like outlet 1 to activate 2 seconds after your trig-
ger device is turned on, program outlet 1's time delay to 02.
If you would like outlet 2 to activate 2 seconds after outlet 1,
program outlet 2's time delay to 04, etc.

3.

The turn off time delay (indicated by the 

OFF

LED being lit).

Program the delays for each outlet to build your "turn off"
sequence.

Enter the PS programming mode

Turn off the devices plugged into the 2 sensing outlets before
programming any of the switched or controlled outlets or
the IPC-6 will not enter PS programming mode.

Press and hold down the 

PROGRAM

button on the front panel

of the IPC-6. While you are holding it down, press the 

SELECT

button. Release both buttons. When you begin program-
ming the IPC-6 will display "PS" only momentarily.

The IPC-6 will light the 

ON

and "Outlet 1" LED's. You are now

ready to program the "turn on" sequence for each switched
outlet.

1.

Select either or both of the trigger buttons (A, B). This will

determine which device(s) will trigger outlet 1 to turn on.

2.

Adjust the "on" time delay. The two buttons to the right of

"TECH TIP"

Devices must be
turned off before

programming any 

of the outlets.

Содержание IPC-6

Страница 1: ...ion All rights reserved Niles and the Niles logo are registered trademarks of Niles Audio Corporation All other trademarks are the properties of their respective owners Because we continually strive to improve our products Niles reserves the right to change product specifications without notice The technical and other information contained herein is not intended to set forth all technical and othe...

Страница 2: ...ens Finally the IPC 6 can control 2 devices that require a switch or relay contact closure for operation e g electric curtains and blinds or low voltage lighting Patents applied for TABLE OF CONTENTS Introduction 1 Features and Benefits 3 Installation Considerations 5 Installation 6 Programming 12 Trouble shooting 18 Specifications 18 I N T E L L I G E N T P O W E R C O N T R O L L E R 1 IPC 6 Int...

Страница 3: ...s One situation is triggered by device A the other situation is triggered by device B You can trigger either the A or the B sequences with a 12 volt DC signal applied to the 12 volt sensing inputs The IPC 6 can remember different delay times for each of its switched outlets and control relays 3 I N T E L L I G E N T P O W E R C O N T R O L L E R TOOLS REQUIRED 1 8 Standard Slotted Screwdriver Wire...

Страница 4: ...hey are low voltage only IMPORTANT Do not connect any signal higher than 30 volts to the trigger inputs with a switched AC outlet on the IPC 6 Installation 1 Select a convenient location for the IPC 6 2 Run all the necessary wiring to the IPC 6 s planned loca tion Label the wires with both their origin which compo nent they power and their destination which of the switched outlets that component w...

Страница 5: ...AND OFF LEDS TRIGGER BUTTONS A AND B SELECT BUTTON 8 I N T E L L I G E N T P O W E R C O N T R O L L E R NILES PROGRAM POWER IPC 6 INTELLIGENT POWER CONTROLLER A TRIGGER B ON OFF 1 2 3 4 5 6 C1 C2 SELECT TIME DIGITAL DISPLAY Shows you the currently selected delay TIME BUTTONS Allow you to adjust the delay between 0 and 99 seconds Press the PROGRAM and the SELECT buttons at the same time to enter t...

Страница 6: ...one of these outlets will trigger the corresponding A or B OFF sequence CONTROLLED 12 VOLT DC OUTPUTS Positive Terminal 1 Ground Terminal 2 SENSING 3 30V AC or DC INPUTS Contact groups provide you with a NORMALLY OPEN N O contact that closes or a NORMALLY CLOSED N C contact that opens when C1 or C2 are activat ed N O Terminal 1 COMMON Terminal 2 N C Terminal 3 CONTACT GROUP ONE CONTACT GROUP TWO N...

Страница 7: ...c actually have 3 power states You can turn them on with a remote control you can place them in standby with a remote con trol and you can use a manual power or vacation switch to turn them completely off You want the IPC 6 to measure what happens to your device when you use the remote con trol Unless you are sure there is not a third power state use the remote control to turn the device on and of...

Страница 8: ...active 2 The turn on time delay indicated by the ON LED being lit I N T E L L I G E N T P O W E R C O N T R O L L E R 14 Program the delays for each outlet to build your turn on sequence Delays are calculated in 1 second increments after your triggering device is turned on or off Therefore if you would like outlet 1 to activate 2 seconds after your trig ger device is turned on program outlet 1 s t...

Страница 9: ...ll the front panel LED s will light for 2 seconds You have completed program ming your IPC 6 Test Test that you have programmed your IPC 6 properly by turn ing on the components plugged into the A trigger outlet The IPC 6 should now activate your other components according to the sequence you have programmed Repeat this test with the component plugged into the B sensing outlet If the IPC 6 fails t...

Страница 10: ...lled 120V AC outlets Low Voltage Inputs 2 3 30V AC DC control inputs Low Voltage Outputs 2 12V DC 0 1A control outputs 2 30V AC DC 5A control output relays Overall Dimensions 17 wide x 2 high x 8 1 4 deep Weight 6 1 4 lbs Troubleshooting 1 You turn on the device plugged into Trigger A or B and nothing happens You have not completed on programming for each controlled outlet Go to page 12 and follow...