Features and Benefits

The IPC-6 offers unique technology never before available. 

Advanced microprocessor design allows unparalleled flexi-
bility and control.

The IPC-6 Accusense

TM

circuitry automatically “locks on” to

tiny differences in power consumption between a compo-
nent’s “on” and “standby” states.

The IPC-6 Powertracker

TM

circuitry will track those tiny dif-

ferences even under varying line voltage conditions.

The IPC-6 Accusense

TM

circuitry will work with all types of

power supplies including switching types.

Advanced arc suppression techniques prevent power relay
contact arcing, ensuring long relay life. 

After a power failure, the IPC-6 will wait for you to again
turn on the system. It does not blindly activate whatever
was happening before the power failure.

The IPC-6 remembers which components you want turned
on in two different situations. One situation is triggered by
device “A”, the other situation is triggered by device “B”.

You can trigger either the “A” or the “B” sequences with a
12 volt DC signal applied to the 12 volt sensing inputs.

The IPC-6 can remember different delay times for each of
its switched outlets and control relays.

3

I

N T E L L I G E N T

P

O W E R

C

O N T R O L L E R

TOOLS

REQUIRED

• 1/8" Standard

Slotted Screwdriver

• Wire Stripper

Total delay time is adjustable from 0 to 99 seconds.

Separate "on" and "off" delay times and sequences can be
programmed into the IPC-6.

The IPC-6's 12 volt DC outputs can operate many of the
Niles automated switchers.

The IPC-6 has 2 sets of normally open and normally closed
low voltage relay contacts controllable by either or both
sequences.

Printed circuit board design assures high reliability.

Ideal for home theater, multiroom audio, home automa-
tion, boardrooms, museum exhibits, and commercial
installations of all types.

Limited two year parts and labor warranty.

Proudly made in the USA. 

4

I

N T E L L I G E N T

P

O W E R

C

O N T R O L L E R

Содержание IPC-6

Страница 1: ...ion All rights reserved Niles and the Niles logo are registered trademarks of Niles Audio Corporation All other trademarks are the properties of their respective owners Because we continually strive to improve our products Niles reserves the right to change product specifications without notice The technical and other information contained herein is not intended to set forth all technical and othe...

Страница 2: ...ens Finally the IPC 6 can control 2 devices that require a switch or relay contact closure for operation e g electric curtains and blinds or low voltage lighting Patents applied for TABLE OF CONTENTS Introduction 1 Features and Benefits 3 Installation Considerations 5 Installation 6 Programming 12 Trouble shooting 18 Specifications 18 I N T E L L I G E N T P O W E R C O N T R O L L E R 1 IPC 6 Int...

Страница 3: ...s One situation is triggered by device A the other situation is triggered by device B You can trigger either the A or the B sequences with a 12 volt DC signal applied to the 12 volt sensing inputs The IPC 6 can remember different delay times for each of its switched outlets and control relays 3 I N T E L L I G E N T P O W E R C O N T R O L L E R TOOLS REQUIRED 1 8 Standard Slotted Screwdriver Wire...

Страница 4: ...hey are low voltage only IMPORTANT Do not connect any signal higher than 30 volts to the trigger inputs with a switched AC outlet on the IPC 6 Installation 1 Select a convenient location for the IPC 6 2 Run all the necessary wiring to the IPC 6 s planned loca tion Label the wires with both their origin which compo nent they power and their destination which of the switched outlets that component w...

Страница 5: ...AND OFF LEDS TRIGGER BUTTONS A AND B SELECT BUTTON 8 I N T E L L I G E N T P O W E R C O N T R O L L E R NILES PROGRAM POWER IPC 6 INTELLIGENT POWER CONTROLLER A TRIGGER B ON OFF 1 2 3 4 5 6 C1 C2 SELECT TIME DIGITAL DISPLAY Shows you the currently selected delay TIME BUTTONS Allow you to adjust the delay between 0 and 99 seconds Press the PROGRAM and the SELECT buttons at the same time to enter t...

Страница 6: ...one of these outlets will trigger the corresponding A or B OFF sequence CONTROLLED 12 VOLT DC OUTPUTS Positive Terminal 1 Ground Terminal 2 SENSING 3 30V AC or DC INPUTS Contact groups provide you with a NORMALLY OPEN N O contact that closes or a NORMALLY CLOSED N C contact that opens when C1 or C2 are activat ed N O Terminal 1 COMMON Terminal 2 N C Terminal 3 CONTACT GROUP ONE CONTACT GROUP TWO N...

Страница 7: ...c actually have 3 power states You can turn them on with a remote control you can place them in standby with a remote con trol and you can use a manual power or vacation switch to turn them completely off You want the IPC 6 to measure what happens to your device when you use the remote con trol Unless you are sure there is not a third power state use the remote control to turn the device on and of...

Страница 8: ...active 2 The turn on time delay indicated by the ON LED being lit I N T E L L I G E N T P O W E R C O N T R O L L E R 14 Program the delays for each outlet to build your turn on sequence Delays are calculated in 1 second increments after your triggering device is turned on or off Therefore if you would like outlet 1 to activate 2 seconds after your trig ger device is turned on program outlet 1 s t...

Страница 9: ...ll the front panel LED s will light for 2 seconds You have completed program ming your IPC 6 Test Test that you have programmed your IPC 6 properly by turn ing on the components plugged into the A trigger outlet The IPC 6 should now activate your other components according to the sequence you have programmed Repeat this test with the component plugged into the B sensing outlet If the IPC 6 fails t...

Страница 10: ...lled 120V AC outlets Low Voltage Inputs 2 3 30V AC DC control inputs Low Voltage Outputs 2 12V DC 0 1A control outputs 2 30V AC DC 5A control output relays Overall Dimensions 17 wide x 2 high x 8 1 4 deep Weight 6 1 4 lbs Troubleshooting 1 You turn on the device plugged into Trigger A or B and nothing happens You have not completed on programming for each controlled outlet Go to page 12 and follow...

Отзывы: