Electrical installation

Electrical connections

Safety

ATTENTION

All work must be carried out by qualified personnel and in accordance with applicable legislation

and regulations.

ATTENTION

It is important that power is disconnected when working with the unit's electrical components.

It is important to check that cables have not been damaged or pinched during connection and use.

Connections list

All electrical connections are made on the right-hand side of the unit, viewed from the front, if mounted

horizontally.

If mounted vertically, the electrical connections are made at the bottom of the unit.

1. Connection of 230V supply (remember electrical grounding)
2. Connection of control panel
3. Connection of PC via a USB AB cable

1

2

3

16

Содержание comfort CT150

Страница 1: ...INSTALLATION INSTRUCTIONS CTS602 LIGHT BY NILAN Comfort CT150 CT200 English Version 3 00 27 09 2018...

Страница 2: ...llation Mounting 13 Positioning of the unit 13 Installation rails 14 Rear installation accessories 14 Side installation accessories 15 Electrical installation Electrical connections 16 Safety 16 Conne...

Страница 3: ...Unit 25 Extract air 26 Supply air 26 Roof stack 26 Balancing 27 Important information 27 Balancing connectors 27 Pressure drop diagram 27 Comfort CT150 CT200 English BY NILAN 3...

Страница 4: ...of the unit always contact an authorised electrical installer to rectify the fault CAUTION Always disconnect mains electricity to the unit before opening the doors e g for installation inspection clea...

Страница 5: ...dk en gb frontpage download dealers The purpose of these instructions is to give the installer advice on correct installation and maintenance of the unit ATTENTION The unit must be started up immediat...

Страница 6: ...ilation required in case of low outdoor temperature Yes No Level At C Is low ventilation required in case of low air humidity Yes No Level Level low air humidity Is high ventilation required in case o...

Страница 7: ...ated in the heat exchanger by the warm extracted air Comfort CT150 CT200 comes as standard with a plate filter for outdoor air and extract air If you want to filter pollen from outdoor air a pollen fi...

Страница 8: ...awing All dimensions are in mm Left version 27 27 20 1000 338 1040 5 1 2 4 3 526 326 93 94 224 535 91 326 94 174 8 125 333 5 Connections 1 Outdoor air 2 Supply air 3 Extract air 4 Discharge air 5 Cond...

Страница 9: ...on 1040 338 1000 5 1 4 3 2 203 95 90 1 325 526 535 5 333 125 92 325 95 137 27 27 20 Connections 1 Outdoor air 2 Supply air 3 Extract air 4 Discharge air 5 Condensate drain Comfort CT150 CT200 English...

Страница 10: ...Outdoor air T2 T7 Supply air sensor 2 Supply air T9 After heating element frost protection 3 Extract air T3 Extract air sensor 4 Discharge air T4 Discharge and de icing sensor 5 Condensate drain T8 Ou...

Страница 11: ...s protecting the unit Pollen filter The unit is supplied as standard with a plate filter If persons in the dwelling suffer from a pollen allergy there is an option for mounting a pollen filter in the...

Страница 12: ...d brackets for vertical mounting For vertical mounting of the unit a wall bracket can be purchased and attached in which the ducts can also be led and concealed By vertical mounting the unit works as...

Страница 13: ...ommended Comfort CT150 is a flexible unit which can be mounted horizontally vertically or at an angle However it is important that the exhaust is always positioned at the bottom see illustration below...

Страница 14: ...is is a simple and quick way of mounting the unit without having to hold it while screwing it into position 1045 mm Rear installation accessories It is possible to buy a mounting bracket for mounting...

Страница 15: ...bracket can be mounted on either the right or the left side The ducts can be lead behind the bracket which provides a nice installation It is possible to mount the control panel on the side bracket i...

Страница 16: ...rical components It is important to check that cables have not been damaged or pinched during connection and use Connections list All electrical connections are made on the right hand side of the unit...

Страница 17: ...nary LAN cable not crossover cable max 50m If it is wished to extend the cable please note the following Installation in the RJ12 plug 1 Empty 2 Empty 3 Green A2 4 Green white B2 5 Brown 12V 6 Brown w...

Страница 18: ...rms The wall bracket is located on the back of the panel and can be detached by loosening the bracket at the bottom of the panel so it can be removed The wall bracket is mounted to the wall with 2 scr...

Страница 19: ...ly This means that you do not have the protection of electrical grounding The electrical grounding can be secured by connecting the plug to an electrical outlet equipped with a ground pin It is also p...

Страница 20: ...in pins 4 and 5 in the control panel s 8 pole plug The user selection can also be used for other functions e g to create imbalance in supply air and extract air ventilation Modbus It is possible to co...

Страница 21: ...overheating 1 A thermostat regulates heat and ensures that the supply air temperature does not go below 1 C 2 A max thermostat switches off the preheating element if the temperature exceeds 50 C By v...

Страница 22: ...flows the condensate tray and from there out of the unit After mounting the water trap its function is tested as follows the unit must be connected to the duct system and the lid must be closed The co...

Страница 23: ...ter trap min 50 mm min 50 mm min 112 5 mm 20 mm 20 mm 20 mm min 170 mm Connections water trap generally Connection of Nilan water trap with ball The water trap can be turned Comfort CT150 CT200 Englis...

Страница 24: ...ll option Connection possibilities with the Nilan water lock 1 Water lock with 32 mm spout 2 Reduction spout to 20 mm 3 Reduction piece to RG 4 Reduction spout for hose Dimensional drawing All dimensi...

Страница 25: ...rking drawing without use of bends and manifolds A manifold box is installed after the unit and the tubes run from this out to the various rooms With NilAIR tubes it is unnecessary to mount sound damp...

Страница 26: ...ned and designed to limit pressure fluctuations in the ventilation system caused by wind impact and also to prevent access by birds and other animals and to ensure that the inlet and closed duct syste...

Страница 27: ...balancing connectors for measuring the supply air and extract air volumes The graph can be used for roughly setting the main air flow for dry operation without condensation precipitation On the extra...

Страница 28: ...7 9798361 maurice nilan ie www nilanireland ie Document no M24_Comfort_CT150 CT200_GB Nilan A S disclaims all liability for errors and omissions in printed instructions and for loss damage or injury a...

Отзывы: