Safety Precautions 

 

 

 

 

 

 

Caution 

 

 

1.  Turn off the power during installation, assembly, connection/disconnection of cables, 

and maintenance.

 

To prevent electric shock and fire, be sure to turn off the POWER switch on the power supply 
device (press the “O” side of the POWER switch) and unplug the power cords before installing or 
assembling the product, connecting or disconnecting cables, replacing the lamp, or performing 
maintenance tasks such as cleaning of the lenses.   

2.  Do not wet the product or allow intrusion of foreign matters. 

Do not wet or spill liquids onto the product, as it may result in malfunction, overheat, or electric 
shock. If water or other liquids are accidentally spilled onto the product, immediately turn off the 
POWER switch (press the “O” side of the POWER switch) and unplug the power cord from the 
wall outlet. Then, wipe off the liquid with a piece of dry cloth. Intrusion of foreign matters into the 
product may also result in malfunctions. If liquids or foreign matters enter the product, do not use 
the product, and contact Nikon. 

 

3.  Weak electromagnetic waves 

The product emits weak electromagnetic waves. Do not install the product near precision 
electronic devices to avoid affecting their performance. If signal reception by a TV or radio is 
affected, move the TV or radio set away from the product.   

4.  Cautions on moving the product 

  When carrying the product, hold the product firmly by the bottom front recess and the bottom 

rear.  

  When moving the product, do not hold by the focusing knobs, eyepiece tube, stage, or dia 

pillar illuminator. The parts may become detached and cause the product to fall, and may also 
result in malfunctions and loss of precision.   

5.  Cautions on assembling the product 

  Take care to avoid pinching your fingers and hands.   

  Scratches and dirt (i.e. fingerprints) on optical components such as lenses and filters will 

degrade the microscope image. When assembling the product, be careful not to scratch or 
directly touch the optical components.   

6.  Cautions on the protruding rack of the rectangular stage 

The stage rack of TI-SR Rectangular Mechanical Stage will protrude when the stage is operated. 
When operating the focus knobs or the nosepiece, be careful not to strike your hands against the 
rack. Contact with the edges of the rack may result in injury.   

7. Disposal 

To avoid biohazard risks, dispose of the product as contaminated equipment, according to the 
standard procedures for your facility.   

   

 

 

Содержание eclipse Ti-S

Страница 1: ...Inverted Microscope Instructions M449 E 07 9 NF 1 ...

Страница 2: ......

Страница 3: ...ort has been made to ensure the accuracy of this manual errors or inconsistencies may remain If you note any points that are unclear or incorrect please contact your nearest Nikon representative Some of the equipment described in this manual may not be included in the set you have purchased If you intend to use any other equipment with this product read the manual for that equipment too When using...

Страница 4: ...or property damage Symbols on the Product The symbols on the product indicate the need for caution at all times during use Before operating a part labeled with the following symbols refer to the instruction manual and read the relevant instructions Symbol Meaning CAUTION HOT This symbol can be found on the top of the dia pillar illuminator and on the 12V 100W lamphouse and cautions the following T...

Страница 5: ...wer Supply The TI PS100W Power Supply device can be used with 100 to 240 VAC at 50 60 Hz and can be used with most wall outlets in the world Under normal use you will not need to pay particular attention to the supplied power voltage TE PS30W Power Supply A or TE PSE30 Power Supply A The input voltage ratings are indicated on the rear panel of the power supply device Before connecting the power co...

Страница 6: ... may be hindered causing the lamphouse to become abnormally hot The bottom of the power supply device becomes hot during use Do not cover the air vents on the side of the power supply device 8 Cautions on lamp replacement When replacing the lamp wait approximately thirty minutes after turning off the lamp and make sure that the lamp and the lamphouse have cooled sufficiently To prevent electric sh...

Страница 7: ... for disinfecting the microscope Never hold a flame near these solvents When using a solvent thoroughly read the instructions provided by the manufacturer and handle correctly and safely Note the following precautions when using solvents with the product Keep solvents away from the lamp the lamphouse the power supply device and any other parts that may become hot Keep solvents away from the produc...

Страница 8: ...ves Do not install the product near precision electronic devices to avoid affecting their performance If signal reception by a TV or radio is affected move the TV or radio set away from the product 4 Cautions on moving the product When carrying the product hold the product firmly by the bottom front recess and the bottom rear When moving the product do not hold by the focusing knobs eyepiece tube ...

Страница 9: ...alling Avoid placing the product in direct sunlight or immediately under the room lights The image quality is degraded in a bright environment due to the extraneous light entering the objective A room light immediately above the microscope may also enter the objective as extraneous light especially when using a condenser lens with a longer working distance i e ELWD and LWD In this case it is recom...

Страница 10: ... the opposite directions at the same time Doing so may damage the product Do not rotate the focus knobs past their limit Doing so may damage the product 6 Protecting the ports The product has multiple ports To keep out extraneous light and dust attach the provided caps to the ports that are not in use ...

Страница 11: ...scopy 24 2 1 Introduction to Microscopy 25 2 2 Sample Configuration 1 Ti U TI DH Dia Pillar Illuminator 100W System Condenser and TI TD Eyepiece Tube B 26 2 2 1 Bright Field BF Microscopy 27 2 2 2 Phase Contrast Ph Microscopy 34 2 2 3 External Phase Contrast Microscopy 40 2 3 Sample Configuration2 Ti S TI DH Dia Pillar Illuminator 30W ELWD S Condenser and TI TS Eyepiece Tube B 45 2 3 1 Bright Fiel...

Страница 12: ... 11 TI DH Dia Pillar Illuminator 100W Operation 77 3 11 1 Condenser Refocusing Clamp 77 3 11 2 Condenser Mount Rotation 77 3 11 3 Pillar Inclination 78 3 11 4 Device Attachment Screw Holes 78 3 12 TI SR Rectangular Mechanical Stage 79 4 Assembly 80 5 Troubleshooting 103 5 1 Image Viewing 103 5 2 Operation 105 5 3 Electrical System 105 6 Daily Maintenance 106 6 1 Cleaning Optical Components 106 6 2...

Страница 13: ...n be selected to suit the application However the lamp the dia pillar illuminator and the power supply device must be used in specific combinations Do not use these devices in an inappropriate combination For combinations of the lamp the dia pillar illuminator and the power supply device refer to page 55 For details on microscopy procedures see Chapter 2 Microscopy For details on the operation of ...

Страница 14: ...se Dia illumination brightness control knob Dia illumination ON OFF switch Left side port Focus knob Coarse Fine Torque adjustment ring for coarse focus knob Lamphouse for dia illumination Fig D LH LC Filter sliders both sides 4 total Dia pillar illuminator Fig TI DH Condenser mount Stage Fig TI SR Nosepiece Fig TI ND6 Stage knob Right side port Focus knob Coarse Fine Coarse focus stopper ring Int...

Страница 15: ...1 4 Ti S Left View Attach a protective cap on the side port when the side port is not in use Lamphouse Dia pillar illuminator Fig TI DS Filter sliders Stage Fig TI SR Nosepiece Fig TI N6 Stage knob Optical path selector knob Main body Fig Ti S Power supply device Fig TI PS30W Eyepiece base unit Fig TI T B Eyepiece tube Fig TI TS Eyepieces both sides Condenser lens Condenser turret Fig ELWD S Conde...

Страница 16: ...ion 100 R Right side 100 B Bottom port 100 L Left side 100 EYE Visual 100 SIDE Visual observation 20 Left side port 80 EYE Visual observation 100 SIDE Left side port 100 Dia pillar illuminator mount A carrying handle is attached for transportation Connector panel rear Right side port Ti U and Ti U B only Fine focus knob Bottom port on the bottom Ti U B only Intermediate magnification selector knob...

Страница 17: ...ceived including interference that may cause undesired operation This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numØrique de la classe A est conforme la norme NMB 003 du Canada Figure 1 7 Microscope Base Rear View Epi fl illumination field diaphragm slider mount Fine focus knob Coarse focus knob Torque adjustment ring for coarse focus knob Left side port Dia illuminati...

Страница 18: ...ase Unit Eyepiece base unit for external phase contrast microscopy A turret for phase contrast rings is provided on the front of the eyepiece base unit The turret has three positions A B and C that can each hold an external phase contrast phase plate The focus can be adjusted independently for each position The turret has screws on its sides for centering the phase contrast rings and clamp screw o...

Страница 19: ...e Tube B Figure 1 13 TI TERG Ergonomic Eyepiece Tube Eyepiece tube with an adjustable binocular that can be inclined to fit the user Like TI TD Eyepiece Tube B this eyepiece tube is equipped with a Bertrand lens The optical path to the eyepieces can be cut off for example when observing with a camera The Bertrand lens can be moved into the optical path for observation of the objective pupil plane ...

Страница 20: ...in stage comes with the following two concentric rings 25 mm bore with oiling notch 40 mm bore TI SAM Attachable Mechanical Stage Figure 1 16 Attachable Mechanical Stage on Plain Stage This stage is attached to the plain stage when using specimen holders The specimen can be moved in the X and Y directions by operating the stage knob Various specimen holders can be used by attaching the following a...

Страница 21: ...or 30W The TI DS Dia Pillar Illuminator 30W has a built in lamphouse but requires a separate condenser The following illustration shows the TI DS Dia Pillar Illuminator 30W with the ELWD S Condenser EN TI DS 30W 6V 30W HALOGEN Figure 1 18 TI DS Dia Pillar Illuminator 30W with ELWD S Condenser D LH LC Precentered Lamphouse LC Requires TI PS100W power supply Lamp cable Condenser mount rotatable Cond...

Страница 22: ...ar Illuminator 30W Figure 1 20 TI C Condenser Turret mounted on TI DS Dia Pillar Illuminator 30W The system condenser can be mounted on the TI DS Dia Pillar Illuminator 30W for HMC observation only Condenser focus knob Condenser focus knob Condenser centering knob Condenser lens 4 types ELWD LWD HMC and CLWD Condenser cassette clamp screws both sides of cassette Condenser turret Condenser cassette...

Страница 23: ...e 1 21 ELWD S Condenser The ELWD S Condenser supports bright field microscopy and phase contrast microscopy It can be used with both 100W and 30W dia pillar illuminators Condenser lens Turret Centering knob Clamp screws both sides Condenser Centering knobs both sides ...

Страница 24: ...knob on the microscope for output voltage control When this switch is turned off the brightness control knob on the front of the power supply becomes enabled and the brightness control knob on the microscope becomes disabled EXTERNAL external control signal input connector Connect the control cable to this connector and the LAMP CTRL connector on the rear of the microscope 1 2 6 8 7 3 4 5 Pin Sign...

Страница 25: ... the connector for connecting the power supply device to a wall outlet Be sure to use the specified power cord for the connection CTRL external control ON OFF switch Turn this switch on to use the brightness control knob on the microscope for output voltage control When this switch is turned off the brightness control knob on the front of the power supply becomes enabled and the brightness control...

Отзывы: