3-46
3
ST
N
3: Quick Station (Quick)
Setup the station quickly without given coordinates
Press the [4] key on the setup menu to
display the screen for inputting a quick
station point.
ST : Station point (defaulted to the Last recorded PT +1)
H I : Height of Instrument
BS : Backsight point
AZ : Backsight azimuth (defaulted to zero)
The Station point (ST) in this function is defaulted to a new point number.
For the new point, MP (0, 0, 0) is stored as the coordinate of the station.
When the ST is changed to a known point, the setup is done on the
coordinate of the point specified.
The backsight point(BS) has no default.
You can leave it blank or input any point
name/number.
The backsight angle(HA) can be changed,
if necessary.
After you input or accept the azimuth for HA, sight the BS and press the
[ENT] key to complete the station setup. The HA will be reset to the input
value when the [ENT] is pressed at the AZ field.
Even if both of ST and BS are known points, this function does not
calculate the backsight angle (AZ) automatically. When you want
the AZ to be calculated between two known points (ST and BS),
you need to use STN/1:Known. (See p.3-37)
ST:1507
HI: 0.0000 m
BS:
AZ: 0.0000g
1
ST:1507
HI: 1.8150m
BS:■
AZ: 0.0000g
1