VBA28001-R.3813.A
- A72 ・ D3100 -
Sweep3 Sweep4
Sweep2
Sweep1
Max.
100mV
Min.
40mV
Max.
100mV
Min.
50mV
Max.
90mV
Min.
50mV
Max.
60mV
Min.
20mV
Tool.(Device)
J61232
Current.detector
Power.supply
(
10
V
5
A
)
3-output.stabilized
.power.supply
Oscilloscope
Power.connector
EP-5A
Operation.check.of.image.sensor.cleaning
Refer.to."Operation.check.of.image.sensor.cleaning".of.ADJUSTMENT.Separate.Volume.
①
.for.details.
•
.Setting.of.oscilloscope
(
In.case.of.YOKOGAWA-made.DL1540
)
INPUT
DC
TRIGGER.MODE
AUTO
TRIGGER.LEVEL
4.0V
TRIGGER.SOURCE CH1
TRIGGER.TYPE
EDGE
CH.POSITION
-4.00div
CH.COUPLING
DC
PROBE
1:1
FILTER(Bandwidth) FULL
FILTER(Smooth)
ON
TIME/DIV
500ms/div
V/DIV
500mv/div
CH1
OFFSET
Adjust.so.that.the.wavy.line.is.
positioned.in.the.center,.and.
easily.viewable.
Standard
User ID:INC