VBA28001-R.3813.A
- A71 ・ D3100 -
Measurement of consumption current value
Refer to "Measurement of consumption current value" of ADJUSTMENT Separate Volume
①
for
details.
Standard:
Main SW/OFF (NOT any button pressed)
200μA or less
Main SW/ON (Half-release timer: OFF)
190μA or less
Main SW/ON (Half-release timer: ON)
250mA or less
Main SW/ON (TFT monitor: Light up)
280mA or less
During LV (Live View)
550mA or less
During recording movies
700mA or less
•
Tool (Device)
Use Nikon product.
Power supply
(10V 5A
)
Digital meter
Converted
power connector
EP-5A
User ID:INC