VAA46003-R.3659.A
- A39 ・ E7900 -
7
. Pattern box
Before using the pattern box, turn its power on to carry out "Aging" approx.
30
minutes: the color temperature should
be
3100
±
20
K by the adjustment with the color meter, and the luminance should be
900
±
20
cd/m
2
by the adjustment
with the luminance meter. When using the pattern box and for a while after its power turns off, the lamp and its
surroundings are subject to high temperatures, so care should be taken when handling.
• Procedure for correcting Pattern Box
Note: Be sure to perform the aging correction.
1
) Measure the measuring point (center of diffusion plate) with the Color Meter (J
63081
).
2
) Adjust the pattern box so that the color temperature should be
3100
±
20
K by using "VR for adjustment of the color
temperature".
3
) Measure the center of the diffusion plate with the Luminance Meter BM-
3000
(J
63068
).
4
) Adjust the pattern box so that the luminance should be
900
±
20
cd/m
2
by using "Knob for luminance adjustment".
5
) Repeat from
1
) to
4
) So that the color temperature should be
3100
±
20
k and luminance should be
900
±
20
cd/m
2
8
. Adjustments required when parts are replaced
Lens Adj.
AWB
CCD
Defects
USB
Firmware
up
Initial image
data
Lens Unit
○
○
○
×
×
×
Optical filter
○
○
○
×
×
×
CCD
○
○
○
×
×
×
CP-
1
○
○
○
○
○
○
○
Adjustment is necessary.
×
Adjustment is not necessary.
Power switch
VR for adjustment of
the color temperature
Knob for luminance
adjustment
Iris unit
Diffusion plate
Area to be measured
Содержание coolpix7900
Страница 77: ...VAA46003 R 3659 A E1 E7900 ...
Страница 78: ...VAA46003 R 3659 A E2 E7900 ...
Страница 79: ...VAA46003 R 3659 A E3 E7900 ...
Страница 80: ...VAA46003 R 3659 A E4 E7900 ...
Страница 81: ...VAA46003 R 3659 A E5 E7900 ...
Страница 82: ...VAA46003 R 3659 A E6 E7900 ...
Страница 83: ...VAA46003 R 3659 A E7 E7900 ...
Страница 111: ...VAA46003 R 3659 A T5 E7900 ジーメンススターチャート ...