8##4#
- E5400 -
The contents of inspection standards and tools for E5400
[1] Inspection standards
················································································
R1 to R6
[2] Tools
··································································································
T1 to T2
Conditions to be set and prepared for inspections
1. Physical stance to measure :
On the applicable product, its lens shall be set
fl
at and its monitor shall be set to vertically stand up.
2. Room temperature and constantly controlled humidity :
25 ± 5
͠
Relative humidity : 65 ± 20 %
3. Battery to be employed :
Primary battery:
Unless otherwise speci
fi
ed, use a Sanyo 2CR5 lithium battery (within four months of manufacture).
Secondary battery:
Use the dedicated rechargeable battery EN-EL1.
(Use after it has been fully charged with the dedicated AC adapter EH-21 or battery charger MH-53.)
4. Standard power supply :
Speci
fi
ed AC power supply EH-53 shall be required.