6.2. Configuration options
Function
10-870
Niko configuration
software (in
development)
Address for video inputs 01 - 16
x
x
Address for video inputs 17 - 64
–
x
Undo assignment of video inputs 01 - 16
x
x
Undo assignment of video inputs 17 - 64
–
x
Step sequence general (for all devices)
–
x
Step sequence individual (for up to 16 internal units)
–
x
Reset factory settings (only for parameters than can be set
with the relevant tool)
x
x
Stepping on/off
–
x
Stepping during speech connection on/off
–
x
Control function for step function
–
x
Control function for image switching
–
x
Control function for backwards stepping
–
x
Automatic stepping on/off
–
x
Time interval for automatic stepping
–
x
Changing up of the video input with the control function (control
function number = video input 01 ... 64) on/off
–
x
Direct switching with free protocols (4 free protocols, including
image and assigned channel number)
–
x
7. TECHNICAL DATA
Dimensions
6U wide (H90 x W105 x D70 mm)
Weight
236 g
Power supply voltage
+24 V ± 8 % (supply and control device)
Housing
Serial flush-mounting housing 6U in compliance with DIN 43880 for DIN rail in
compliance with DIN EN 60715 TH35
Allowable ambient temperature
+5 °C to +40 °C
Air humidity
0 % to 93 % RH, no dew formation
Input current
I(a) = 0,1 mA
Max. input current
I(Pmax) = 20 mA
6-wire technique required!