3. I

NSTALLATION

 

 

3.1  Inspection:

  Inspect  the  AVR  upon  receipt.  The  packaging  is 

recyclable; save it for reuses or disposes of it properly. 

3.2  Placement:

  Install  the  AVR  in  controlled  area  with  adequate  air 

flowing  and  free  of  excessive  dust.  Do  not  operate  the  AVR  at 
outdoor area. 

3.3  Utility  Power:

  Be  sure  the  polarities  and  types  of  the  receptacles 

match  the  unit.  Beside  this,  keep  the  capacity  of  this  unit  is  higher 
than  protected  loads.  If  the  capacity  of  AVR  unit  is  not  sufficient, 
input circuit breaker will be opened. 

 

4. O

PERATION

 

4.1 Switch on: 

When utility input is connected to the AVR, press “ON” button to turn 

on  the  AVR.  After  that,  connect  the  electrical  cords  of  the 
equipments that will be used (such as computer or monitor) to the 
rear panel of AVR unit. 

4.2 Switch off: 

Press the “OFF” button to turn off the AVR. 

4.3 “Over load Protection” 

When  the  unit  is  working  under  over  load  situation,  the  input  power 

breaker will be opened to protect the unit itself.   

Warming: 

Once the circuit breaker is opened, please turn on the unit 

again  after  60  sec  to  let  the  breaker  be  fully  cooling  down.  This 
way can extend the life of switch breaker. 

4.4 “Output short Protection” 

When  the  output  loads  are  shorted,  the  input  power breaker  will  be 

opened to protect the unit itself.   

Warming: 

Once the circuit breaker is opened, please turn on the unit 

again  after  60  sec  to  let  the  breaker  be  fully  cooling  down.  This 
way can extend the life of switch breaker. 

 

 
 
 
 
 
 
 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание NRG AVR 1200

Страница 1: ...ECIFICATIONS 4 Please read and save this manual Thank you for selecting this automatic electronic voltage regulator AVR It provides you with a perfect protection for connected equipment The manual is a guide to install and use the AVR It includes important safety instructions for operation and correct installation of the AVR If you should have any problems with the AVR please refer to this manual ...

Страница 2: ...ou with microprocessor controlled Automatic Voltage Regulation function It can supply you with pure stabile power supply and eliminating the connected loads damaged caused by power problem 2 1 OFF mode no indicator The situation caused by 1 Power switch is turn off 2 Circuit breaker is tripped 3 No utility power 2 2 Normal mode indicator Green The indicator will illuminate when the utility input i...

Страница 3: ...on When utility input is connected to the AVR press ON button to turn on the AVR After that connect the electrical cords of the equipments that will be used such as computer or monitor to the rear panel of AVR unit 4 2 Switch off Press the OFF button to turn off the AVR 4 3 Over load Protection When the unit is working under over load situation the input power breaker will be opened to protect the...

Страница 4: ... 240V Typical 7 OUTPUT Frequency 50 or 60Hz Spike Protection 50 1000 joules optional Overload Protection Input Circuit breaker protection PROTECTION Short Circuit Input Circuit breaker protection Net weight Kg lbs 1 6 3 52 1 8 3 96 PHYSICAL Dimension mm WxDxH 123 136 102 Ambient operation 3 500 meters max elevation 0 95 humidity non condensing 0 40 Audible Noise 40dBA 1 meter from surface ENVIRONM...

Страница 5: ... σταθεροποιητή NRG AVR Σας παρέχει απόλυτη ασφάλεια σε όλα τα συνδεδεµένα φορτία του Το εγχειρίδιο αυτό θα σας βοηθήσει να θα εγκαταστήσετε και να χρησιµοποιήσετε τον σταθεροποιητή σας Περιέχει σηµαντικές οδηγίες ασφαλείας για την λειτουργία του καθώς και για την σωστή του εγκατάσταση Εάν έχετε οποιοδήποτε πρόβληµα µε τον σταθεροποιητή NRG AVR παρακαλούµε συµβουλευτείτε το εγχειρίδιο αυτό και εάν ...

Страница 6: ...ηση µε έλεγχο µε µικροεπεξεργαστή Σας παρέχει καθαρή σταθερή ισχύ και ελαχιστοποιεί τα προβλήµατα του εξοπλισµού σας που οφείλονται στις διακυµάνσεις της τάσης 2 1 OFF εν υπάρχει σήµανση Η κατάσταση αυτή δηµιουργείται από τα εξής 1 Ο διακόπτης είναι στην θέση off 2 Υπάρχει πρόβληµα στον ασφαλειοδιακόπτη 3 εν υπάρχει ισχύς 2 2 Normal mode Πράσινη σήµανση Η σήµανση αυτή είναι αναµµένη όταν όλα λειτο...

Страница 7: ...ειοδιακόπτης 4 ΛΕΙΤΟΥΡΓΙΑ 4 1 Εκκίνηση Βάλτε τον σταθεροποιητή στην παροχή και πιέστε το κουµπί ΟΝ Κατόπιν συνδέστε στο πίσω µέρος του σταθεροποιητή τα καλώδια των µηχανηµάτων που θέλετε να υποστηρίξετε When utility input is connected to the AVR press ON button to turn on the AVR 4 2 Κλείσιµο Πιέστε το κουµπί OFF 4 3 Προστασία από υπερφορτώσεις Όταν ο σταθεροποιητής έχει κάποια υπερφόρτωση ανοίγει...

Страница 8: ...or 60Hz Τάση 110V 115V 120Vor 220V 230V 240V Typical 7 ΕΞΟ ΟΣ Συχνότητα 50 or 60Hz Υπερτάσεις 50 1000 joules optional Υπερφορτώσεις Ασφαλειοδιακόπτης εισόδου ΠΡΟΣΤΑΣΙΑ Βραχυκύκλωµα Ασφαλειοδιακόπτης εισόδου Βάρος Kg lbs 1 6 3 52 1 8 3 96 ΙΑΣΤΑΣΕΙΣ ιαστάσεις mm WxDxH 123 136 102 Περιβάλλον λειτουργίας 3 500m max υψόµετρο 0 95 υγρασία 0 40C Θόρυβος 40dBA 1m από την επιφάνεια ΠΕΡΙΒΑΛΛΟΝ Συνθήκες αποθ...

Страница 9: ...4 ...

Отзывы: