HR Series
Operating & Safety Instructions
English/USA – 11/09
Original Instructions
32
4.5
CAGE WEIGH SYSTEM
4.5.1 LOAD
CELL
VERSION
The Niftylift HR21 Hybrid is fitted with an electronic load cell. This load cell is a moment-independent,
redundant design. This means that independent of the load position inside the cage of the machine, the
actual load is measured and if pre-configured limit values are exceeded, warnings will be activated.
“Redundant design” means that the load cell design incorporates dual channels that monitor each
other. The design of the unit meets the requirements of both EN280 and EN954-1 class III.
4.5.2 FUNCTION
The machine informs the operator, via the load cell output, of the current state of the machine with
regard to cage load. There are three output lamps:
green
,
amber
and
red
. The three lamps for the load
cell are located on the cage control panel (see section 4.3.1). These lamps can be interpreted as
follows:
Lamp
Description
Load
value
Machine Behaviour
Constant green
Load in the cage does not exceed
80% of safe working load
180kg or
less
Normal operation
Constant amber
Load in the cage is 80-90% of
safe working load
180kg to
203kg
Normal operation
Flashing amber
Load in the cage is 90% of safe
working load
203kg to
225kg
Normal operation
Flashing red (Safety
Warning Lamp)
Load in the cage has exceeded
safe working load
Above
225kg
Controls isolated –
safely remove excess load
to restore normal operation
4.5.3
CALIBRATION, INSPECTION AND MAINTENANCE
Calibration, maintenance and repair of the Niftylift HR21 Hybrid cage load cell requires specialist
knowledge and equipment.
For this reason, no part of the Niftylift HR21 Hybrid cage-weigh
system can be adjusted, repaired or inspected by the operator.
All enquiries relating to calibration, inspection or maintenance should be directed to Niftylift or one of
Niftylift’s approved dealers. Contact details are listed in Section 1.4